4. Storing your Garden Spring Pump
Storage:
The pump should be stored out of the reach of children.
1. Before the frosty season begins, take the pump out of the pond
and clean it.
2. To avoid difficulties when starting up in the spring, we recom-
mend storing the pump in a frost-free location in a container
filled with water. The mains plug must not be submerged.
Disposal:
The product must not be added to normal household waste.
(in accordance with
It must be disposed of properly.
RL2002/96/EC)
5. Cleaning
Cleaning the pump:
1. Remove the filter housing
clean it.
2. Turn the pump inlet
motor housing
3
8
3. Take the impeller
4. Push the cleaned impeller
5. Push the pump inlet
and tighten it clockwise. (If the pump is to suck from under-
neath, the thread must face downwards).
5
6
6. Push the filter housing
6. Trouble-shooting
Fault
Possible cause
The pump delivers no water
Mains plug not plugged in.
Impeller unit is blocked.
Impeller running in the wrong
direction due to insufficient water.
Pump installed out of water
and not filled.
The pump delivers a reduced
Filter housing dirty.
water flow
10
CAUTION! Electric shock !
Risk of injury due to mains electricity.
v Before cleaning the pump, unplug the it from
the mains.
3
from the motor housing
5
anticlockwise and pull it vertically off the
6
(bayonet socket).
8
6
out of the motor housing
and clean it.
8
back into the motor housing
5
vertically on to the motor housing
3
back on to the motor housing
CAUTION! Electric shock!
Risk of injury due to mains electricity.
v Before fault-finding, unplug the pump at the
mains.
Remedy
v Plug in mains plug.
v Clean pump.
v Disconnect from the mains
and top up with water.
v Fill the inlet hose with water.
v Clean filter housing.
CAUTION!
If any other faults arise, please contact GARDENA Service.
7. Accessories
GARDENA Underwater lights
UL 20 / UL 20 S Set
GARDENA radio control set

8. Technical Data

Mains voltage/mains frequency 230 V AC / 50 Hz
Rated power
Power cable
Flow
Max. delivery head
6
, and
Max. submersion depth
Pump connection
Media temperature
6
.
9. Service / Guarantee
6
Guarantee
6
.
Work on the electrical parts must only be carried out by
GARDENA Service Centres.
Illumination of garden springs or objects
in / on the pond.
Start water features and lighting from
the terrace or your living room.
WP 600 (art. 7630)
WP 1200 (art. 7631)
230 V AC / 50 Hz
8 W
16 W
10 m; H05-RN-F
10 m; H05-RN-F
600 l/h
1200 l/h
1,2 m
1,6 m
1 m
1 m
G 1/2
G 1/2
4 °C – 35 °C
4 °C – 35 °C
GARDENA guarantees this product for 3 years (from date of
purchase). This guarantee covers all serious defects of the unit
that can be proved to be material or manufacturing faults.
Under warranty we will either replace the unit or repair it free of
charge if the following conditions apply:
The unit must have been handled properly and in keeping with
the requirements of the User's Manual.
• Neither the purchaser or a non-authorised third party have
attempted to repair the unit.
The feed impeller is a wearing part and is not covered by the
warranty.
This manufacturer's guarantee does not affect the user's existing
warranty claims against the dealer/ seller.
If you have any problems with your Fountain Pump Set,
please contact our Service or return the defective unit together
with a short description of the problem – in case of guarantee,
with a copy of the receipt – postage paid to one of the
GARDENA Service Centres listed on the back of this leaflet.
art. 7952
art. 7958
art. 7874
WP 1800 (art. 7632)
230 V AC / 50 Hz
30 W
10 m; H05-RN-F
1800 l/h
2,0 m
1 m
G 1/2
4 °C – 35 °C