Fronius OPT/i TWIN SyncBox Kullanım Talimatları Kılavuzu - Sayfa 11
Kaynak Sistemi Fronius OPT/i TWIN SyncBox için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Fronius OPT/i TWIN SyncBox 12 sayfaları.
Ayrıca Fronius OPT/i TWIN SyncBox için: Kullanım Talimatları Kılavuzu (12 sayfalar)
Installation
Installation
1
2
3
4
5
Apply the following settings on the control panel of power source 1:
-
Select Defaults/System/Next Page/TWIN Setup/Power Source 1
-
Set Process Parameters/Components & Monitoring/Components/Cooling Unit
Operating Mode to ON
Activate the following settings on the control panel of power source 2:
-
Select Defaults/System/Next Page/TWIN Setup/Power Source 2
-
Set Process Parameters/Components & Monitoring/Components/Cooling Unit
Operating Mode to ON
Switch off power sources
Connect power sources of OPT/i Twin SyncBox and wirefeeder as shown in the appli-
cation example
-
TWIN welding characteristics are now activated and the welding process is syn-
chronized immediately
Switch on the power source
11