Fronius OPT/i TWIN SyncBox Kullanım Talimatları Kılavuzu - Sayfa 8

Kaynak Sistemi Fronius OPT/i TWIN SyncBox için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Fronius OPT/i TWIN SyncBox 12 sayfaları.
Ayrıca Fronius OPT/i TWIN SyncBox için: Kullanım Talimatları Kılavuzu (12 sayfalar)

Fronius OPT/i TWIN SyncBox Kullanım Talimatları Kılavuzu
Marks of conformity
Dimensions L × W × H
Weight
Notes on the
Function:
function of the
OPT/i TWIN SyncBox synchronizes the welding processes of both power sources for
OPT/i TWIN Sync-
TWIN welding. When connected to the OPT/i TWIN SyncBox, characteristics that were es-
Box
pecially optimized for this will be activated at the power sources.
Remote controls:
If a remote control is connected to the system, the settings on the remote control only affect
the power source that the remote control is connected to. For both power sources to be
controlled via remote control, a remote control must be connected to each power source.
Troubleshooting:
The OPT/i TWIN SyncBox does not have a troubleshooting function—an error in power
source 1 would therefore not automatically affect/deactivate power source 2.
Cooling:
For the welding system to be adequately cooled, both power sources need to be switched
on. Even when only one power source is used for the welding process (both parts of the
CU 2000i Pro /MC must be supplied from the respective power source so that the cooling
of the welding system can function properly).
Firmware update:
The OPT/i TWIN SyncBox uses its own firmware (not identical with the firmware of the
power source). Always update the OPT/i TWIN SyncBox firmware separately.
8
CE
450 x 350 x 90 mm
17.72 x 13.78 x 3.54 inch
3.6 kg
7.94 lb.