Gardena 14772 Operatör El Kitabı - Sayfa 8
Elektrikli Alet Gardena 14772 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. Gardena 14772 13 sayfaları. Battery pruning lopper/battery telescopic pruning lopper
4.2.2 To clean the battery charger:
v Clean the contacts and the plastic parts with a soft and dry cloth.
5. STORAGE
5.1 To put into storage:
The product must be stored away from children.
1. Remove the battery.
2. Slide the protective cover over the blade.
3. Charge the battery.
4. Clean the lopper, the battery and the battery charger
(see 4. MAINTENANCE).
5. Store the lopper, the battery and the battery charger in a dry, enclosed
and frost-free place.
6. TROUBLESHOOTING
DANGER!
Cutting injury due to the blade!
Risk of cut injury due to accidental starting.
v Use gloves.
v Remove the battery.
v Slide the protective cover over the blade.
6.1 Troubleshooting table:
Problem
Possible Cause
Start lever cannot
Start lever is stuck.
be pushed
Lopper does not start
Battery is empty.
or stops.
(L1)
LED
blinks green
[ Fig. O4 ]
Lopper does not start
Battery temperature is outside
or stops.
the permissible temperature
Error-LED
(Wp)
lights red
range.
[ Fig. O4 ]
There are drops of water or
moisture between the battery
contacts.
Obstacle blocks the motor.
Lopper does not start
Lopper is defective.
or stops.
(Wp)
Error-LED
blinks red
[ Fig. O4 ]
Lopper does not start
Battery is not put completely
or stops.
into the battery holder.
(Wp)
Error-LED
does not
light [ Fig. O4 ]
Battery is defective.
Lopper is defective.
Charging is not possible.
Battery is not slid onto the
Battery charge indicator
(Lc)
charger correctly.
lights continuously green
Battery contacts are dirty.
[ Fig. O3 ]
Battery temperature is outside
the permissible temperature
range.
Battery is defective.
Charging is not possible.
Mains plug of the charger is
(Lc)
Battery charge indicator
not plugged in correctly.
does not light
Mains socket, mains cable or
[ Fig. O3 ]
charger is defective.
NOTE:
Repairs must only be done by the GARDENA service departments or
specialist dealers approved by GARDENA.
14
v For any other malfunctions please contact the GARDENA service
department.
7. TECHNICAL DATA
Lopper
Max. branch diameter
Max. cuts per battery charge
Range of extension of
the telescopic tube
Max. Height (with telescopic
tube extended)
Weight (without Battery)
Sound pressure level L
Uncertainty k
Sound power level L
measured/guaranteed
Uncertainty k
Hand/arm vibration a
Uncertainty k
Measuring process complying with:
Remedy
exposure. The vibration emission value can vary during actual use of the electric power
v Loosen the start lever.
tool depending on the ways in which the machine is used. As a safety measure, you
should work with the machine for a maximum of 1 hour without interruption.
v Charge the battery.
System Battery
PBA 18V 2.0Ah W-B
v Wait until the battery
Battery voltage
temperature is between
0 °C – 35 °C again.
Battery capacity
v Remove the water drops or
Number of cells (Li-Ion)
moisture with a dry cloth.
Appropriate POWER FOR ALL
system Battery Chargers
v Remove the obstacle.
v Contact the GARDENA
Battery Charger
Service.
AL 1810 CV P4A
Mains voltage
v Put the battery completely
Mains frequency
into the battery holder until
it audibly engages.
Rated power
v Replace the battery.
Battery charging voltage
v Contact the GARDENA Service.
Max. battery charging
current
v Slide the battery onto the
charger correctly.
Battery charging time
(approx.)
v Clean the battery contacts
(e. g. by connecting and dis-
connecting the battery several
times. Replace the battery if
necessary.
Permitted charging
temperature range
v Wait until the battery
temperature is between
Weight according to
0 °C – + 35 °C again.
EPTA-Procedure 01:2014
v Replace the battery.
Protection class
v Insert the mains plug com-
Appropriate POWER FOR ALL
pletely into the mains socket.
system Batteries
v Check the mains voltage.
Let the charger be checked
if necessary by an authorised
8. ACCESSORIES / SPARE PARTS
specialist dealer or the
GARDENA Service.
GARDENA Extension tube
Unit
Value
(Art. 14772)
mm
28
PBA 18V 2.0Ah W-B
400
PBA 18V 2.5Ah W-B
500
PBA 18V 3.0Ah W-B
600
PBA 18V 4.0Ah W-C
800
PBA 18V 5.0Ah W-C
1000
PBA 18V 6.0Ah W-C
1200
cm
–
cm
110
kg
1.9
65
1)
dB (A)
pA
3
pA
:
2)
WA
76 / 79
dB (A)
3
WA
≤ 2.5
1)
m/s
2
vhw
1.5
vhw
EN IEC 62841-4-2
1)
NOTE: The stated vibration emission value has been measured according to
a standardised test procedure and can be used for comparison of one electric
power tool with another. It can also be used for preliminary evaluation of
Unit
Value (Art. 14902)
V (DC)
18
Ah
2.0
5
AL 1810 CV / AL 1815 CV / AL 18V-20 /
AL 1830 CV / AL 1880 CV
Unit
Value (Art. 14900)
V (AC)
220 – 240
Hz
50 – 60
W
26
V (DC)
18
mA
1000
PBA 18V 2,0Ah W-B
min.
115
PBA 18V 2,5Ah W-B
min.
136
PBA 18V 4,0Ah W-C
min.
228
°C
0 – 35
kg
0.17
PBA 18V
To extend Art. 14774 or as
a replacement.
Value
Value
(Art. 14774)
(Art. 14776)
28
28
400
400
500
500
600
600
800
800
1000
1000
1200
1200
215 – 255
320 – 360
255
360
3.4
4.1
63
57
3
3
77 / 80
77 / 80
3
3
≤ 2.5
≤ 2.5
1.5
1.5
RL 2000/14/EC / S.I. 2001/1701
2)
/ II
Art. 14772-20.630.00
available via GARDENA
Service