Gardena ErgoJet 2500 Kullanım Talimatları Kılavuzu - Sayfa 6

Üfleyici Gardena ErgoJet 2500 için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Gardena ErgoJet 2500 10 sayfaları. Electric blower/vac
Ayrıca Gardena ErgoJet 2500 için: Kullanım Talimatları Kılavuzu (18 sayfalar), Kullanım Talimatları Kılavuzu (19 sayfalar), Kullanım Talimatları Kılavuzu (19 sayfalar), Kullanım Talimatları Kılavuzu (17 sayfalar), Kullanım Talimatları Kılavuzu (9 sayfalar), Operatör El Kitabı (8 sayfalar)

Gardena ErgoJet 2500 Kullanım Talimatları Kılavuzu
Do not vacuum stones, gravel, metal, broken glass, etc. Proper use of
the unit will reduce possible personal injury and/or damage to the unit.
Do not attempt to vacuum water or other liquids. Water or other liquids
entering a power tool will increase the risk of electric shock.
Never run the unit without the proper equipment attached.
When used as a vacuum, always install vacuum tubes and collection bag
assembly. Make sure the collection bag assembly is completely zipped when
unit is running to avoid flying debris. Use only recommended attachments.
Do not vacuum discarded matches, cigars, cigarettes, or ash from
fireplaces, barbecue pits, brush piles, etc. Avoid situations which could
set the collection bag on fire. To avoid spreading fire, do not use blower near
leaf or brush fires, fireplaces, barbecue pits, ashtrays, etc.
Always use the shoulder strap when vacuuming. This will help maintain
control of the power tool.
Check air intake openings, elbow tube, and vacuum tubes frequently,
always with the unit stopped and the power source disconnected.
Keep vents and tubes free of debris which can accumulate and restrict proper
air flow. Do not use with any opening blocked. Keep free of dust, lint, hair and
anything that may reduce air flow.
Additional safety warnings
DANGER! Small parts can be easily swallowed. There is also a risk that
the polybag can suffocate toddlers. Keep toddlers away when you
assemble the product.
DANGER! This product makes an electromagnetic field while it operates.
This field may under some conditions interfere with active or passive
medical implants. To decrease the risk of conditions that can possibly
injure or kill, we recommend persons with medical implants to speak
with their physician and the medical implant manufacturer before you
operate the product.
2. ASSEMBLY
WARNING! Stop the unit and unplug the extension cord
before opening the inlet cover or attempting to install or
remove the blower tube or vacuum tubes.
The motor must be stopped and the impeller blades no longer turning to
avoid serious injury from the rotating blades.
Assembling for blower use:
Fitting the blower tube [ Fig. A1 ]:
NOTE: A safety switch will prevent the unit from starting if the blower
1
tube
is not installed correctly.
1. Align the grooves on the blower tube
outlet
2
.
1
2. Push the blower tube
onto the blower outlet
place.
The blower tube is secured to the blower outlet with the tube release
button
3
.
1
To remove the blower tube
, press the tube release button
out the blower tube
1
at the same time.
Fitting the intake cover [ Fig. A2 ]:
NOTE: A safety switch will prevent the unit from starting if the intake cover
4
is not latched closed.
4
1. Place the intake cover
on the lower opening of the garden blower
and turn the intake cover
4
clockwise up to the stop (bayonet fasten-
ing).
2. Tighten the fastening screw
5
To remove the intake cover
4
, loosen the fastening screw
intake cover
4
anti-clockwise and remove it.
Assembling for vacuum use:
Fitting the vacuum tube [ Fig. A3 / A4 ]:
CAUTION! Do not use the vacuum
ß
the upper tube
.
6b
1. Align the seams of the lower tube
ß
ß
2. Press the tubes
/
together until they are fully engaged.
6b
6 a
NOTE: A safety switch will prevent the unit from starting if the vacuum
6
tube
is not installed correctly.
6
3. Place the vacuum tube
on the lower opening of the garden vacuum
and turn the vacuum tube
6
clockwise up to the stop (bayonet fastening).
4. Tighten the fastening screw
5
6
To remove the vacuum tube
, loosen the fastening screw
vacuum tube
6
anti-clockwise and remove it.
Attaching the collection bag [ Fig. A5 ]:
NOTE: A safety switch will prevent the unit from starting if the elbow tube
7
is not installed correctly.
10
1
with the grooves on the blower
2
until it snaps into
3
and pull
.
5
, turn the
6
unless the lower tube
ß
to fitted to
6 a
ß
ß
and upper tube
.
6 a
6b
.
5
, turn the
1. Align the grooves on the elbow tube
outlet
2
.
2. Press the elbow tube
7
onto the blower outlet
place.
The collection bag is secured to the blower outlet with the tube release
button
8
.
3. Clip the collection bag
9
into both loops
9
To remove the collection bag
, press the tube release button
out the elbow tube
7
at the same time.
Attaching the shoulder strap [ Fig. A6 ]:
For extra support when using your unit as a vacuum, a shoulder strap is
included with your unit. Attach the strap to the unit before operation. Snap
q
the hook onto the retainer
.

3. OPERATION

WARNING! Do not use the unit without the tubes or collec-
tion bag properly attached to avoid flying debris and/or
impeller contact which can cause serious injury.
Always wear gloves and use eye protection to prevent rocks or debris
from being blown or ricocheting into the eyes and face which can result
in blindness or serious injury.
Cables:
Use only 1.00 mm
size cable up to 40 metres length maximum.
2
Maximum rating:
1.00 mm
size cable
2
ErgoJet 3000 (EJ3000): 3000 W
ErgoJet 2500 (EJ2500): 2500 W
Mains cables and extensions are available from your local approved service
centre. Only use extension cables specifically designed for outdoor use.
Connecting the unit [ Fig. O1 / O2 ]:
CAUTION! To avoid damage to the plug, the extension cable must be
inserted into the cable lock.
1. First make a loop with the extension cable
e
cable lock
and pull the extension cable tight.
2. Connect the unit's plug to the extension cable.
3. Connect the extension cable to a 230-V mains socket.
Starting the unit [ Fig. O3 ]:
To start:
v Move the ON/OFF switch
r
to the ON position.
The unit starts.
NOTE: For ErgoJet 3000 (EJ 3000) only: The motor speed can be
increased or decreased by using the variable speed control
WARNING! To avoid causing damage to the unit, only use the variable
speed control in blow mode. DO NOT attempt to use the variable speed
control in vacuum mode. Lower speeds during vacuum use could allow
debris to build up, stall the motor and cause unit failure.
To stop:
r
v Move the ON/OFF switch
to the OFF position.
The unit stops.
Work positions:
Blow mode [ Fig. O4 ]:
Use your unit as a blower for sweeping debris or grass clippings from
driveways, sidewalks, patios, etc. Also, for blowing grass clippings, straw,
or leaves into piles, or removing debris from corners, around joints, or
between bricks.
For ErgoJet 3000 (EJ 3000) only:
Use the variable speed control to increase or decrease the motor speed
during blower use.
Direct air flow by directing the blower tube down or to one side.
Always work away from solid objects such as walks, large stones, vehicles,
and fences.
Clean corners by starting in corners and moving outward. This will help
prevent an accumulation of debris which could fly into your face. Be careful
when working near plants. The force of the air could damage tender plants.
Vacuum mode [ Fig. O5 ]:
Use your unit as a vacuum to pick up dry material such as leaves, grass,
small twigs, and bits of paper.
7
with the grooves on the blower
2
until it snaps into
0
on the vacuum tube 
6
.
8
and pull
w
, thread the loop into the
t
.