alkitronic CLSD 200 Kullanım ve Bakım Kılavuzu - Sayfa 7

Test Ekipmanları alkitronic CLSD 200 için çevrimiçi göz atın veya pdf Kullanım ve Bakım Kılavuzu indirin. alkitronic CLSD 200 16 sayfaları. Mounting documentation system

4. Program preparation / settings

4.1
Parameter table alkitronic® MDS tool
Type
Bluetooth
Torque
min
Name
Nm
(10 % v. M
HSD 100
HSD100...
100
HSD 200
HSD200...
200
HSD 400
HSD400...
400
CLSD 100
CLSD100...
100
CLSD 200
CLSD200...
200
CLSD 400
CLSD400...
400
EASD 100
EASD100...
100
EASD 200
EASD200...
200
EASD 400
EASD400...
400
4.2

Starting Sensor electronics

Check charging state of the battery (Graphic 2).
Before starting the battery for the sensor electron-
ics should be fully charged, so that an operating
time of approx. 8 hours is ensured. Charging time
approx. 3 hours.
4.2.1 Updating / synchronisation of time zones, date and
time settings with the alkitronic® APP vornehmen (see also
p. 15, position 6.1.2).
For each program executed the current date in
the format yy/mm/dd/hh/mm is stored and docu-
mented. Other data stored is listed in the program
descriptions.

4.2.2 Operation Sensor electronics

Press key Start or <Enter> (Graphic 1). Select required program
items and follow the menu guide (see pos. 3.1 left side).
5. Bolting programs
Program overview
1 Torque-controlled bolting
2 Bolting as per torque-controlled or angular process
3 Checking the torque or breakage torque
4 Definition of the required bolting angle
5 Bolting with display of actual torque
1 Torque-controlled bolting
5 Bolting with display of actual torque
1 Torque-controlled bolting
5 Bolting with display of actual torque
MDS
Mounting Documentation Systems
Torque max
Switching toque
threshold
Nm
Nm
max.)
D
1000
50
2000
100
4000
200
1000
50
2000
100
4000
200
1000
50
2000
100
4000
200
MDS Tools
HSD
HSD
HSD
HSD
HSD
CLSD
CLSD
EASD
EASD
5.1

Bolting program 1

For all MDS product
range products
Make the program
selection in the
main menu.
5.1.1 Application description
Boltings are tightened with a torque target setting and simul-
taneously monitored. The target value for the torque can be
entered within a tolerance range. The target torque value is
pre-defined; and always the currently applied torque value
is stored in memory.
5.1.2 Parameter setting
Target torque
Minimum torque
Maximum torque
Number of bolted joints
When setting parameters please check for plau-
sibility! The value of the desired torque should
therefore correctly be between the minimum and
maximum torque values.
>
Target Torque
min. Torque
max. Torque
Display examples Parameter settings
5.1.3 Process description
During the bolting process the torque is increased continu-
ously. As soon as the torque reaches the switching on level
(value see parameter table 4.1) the program will show the
most current maximum torque. If the torque exceeds the pre-
defined minimum torque the user is notified by a visualization
lasting two seconds with a green light and single continuous
signal tone once.
If the currently measured torque increases further and ex-
ceeds the predefined maximum torque, the user is notified
by a single continuously fluctuating signal tone and the
lighting of a red signal light. Only when the current torque
drops below the maximum predefined value or the <Enter>
key is pressed, the warning will be terminated. If the current
drops below the switching level the current bolting data set
is stored in memory.
7
The parameters on the left-
must all be entered to ensure
correct data recording and
evaluation.
>
Numbers
Start
Back