3. INSTALLATION
3.1 HOW TO INSTALL THE UNIT
CAUTION
• There are sharp edges that can cause serious cuts.
• When lifting the air conditioner, it is HEAVY.
Use 2 peoples to lift.
For existing sleeve, you should measure the wall sleeve
dimensions.
You can install the new air conditioner according to these
installation instructions to achieve the best performence. All
wall sleeves used to mount the new air conditioner must be in
good structural condition and have the rear grille that securely
attaches to the sleeve or the flange of the sleeve to secure the
new air conditioner.
• To avoid vibration and noise, make sure the unit is installed
securely and firmly.
A. BEFORE ATTACHING THE FRONT
GRILLE TO THE SLEEVE, IF YOU WANT
TO PULL OUT THE FILTER UPWARD;
1. There should be no obstacle, like a fence, within 20" which
might restrict heat radiation from the condenser.
B. IF YOU WANT TO PULL OUT THE FILTER
DOWNWARD;
The grille is already designed for that way.
1. Install the unit a little obliquely outward not to leak the
condensed water into the room (about 1/2" or 1/4" bubble
with level).
2. Install the unit with its bottom portion 30~60" above the floor
level.
3. The power cord must be connected to an independent
circuit. The green wire must be grounded.
Dimension of air conditioner
Dimension of sleeve assembly (optional)
INSULATION
COOLED
AIR
INTAKE
AIR
1/4" Bubble
of the level
—17—
1,066mm(42")
406mm
(16")
318mm
(12
1
/
")
2
505mm
(20")
1066mm
(42")
406mm
(16")
y
318mm
(12
1
/
")
2
y
SLEEVE
WALL
HEAT
RADIATION
y
WALL
Over 20"
1/4" Bubble
Level