Fujitsu Suelo AGY40-KV Kullanım Kılavuzu - Sayfa 7

Klima Fujitsu Suelo AGY40-KV için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Fujitsu Suelo AGY40-KV 13 sayfaları.
Ayrıca Fujitsu Suelo AGY40-KV için: Kullanım Kılavuzu (13 sayfalar)

Fujitsu Suelo AGY40-KV Kullanım Kılavuzu
• How to set to blow out air from the upper and lower air outlets.
Air Outlet Selection switch
Upper airfl ow
NOTES:
• Set the air outlet selection switch to the end. Otherwise, air outlet
cannot be selected as intended.
Description of operation
Operation Mode
Airfl ow
Upper and lower
airfl ow
Cooling
Upper airfl ow
Upper and lower
Dry
airfl ow
Upper and lower
airfl ow
Heating
Upper airfl ow

6. TIMER OPERATIONS

NOTES: When [
] indicator on the indoor unit blinks, set the clock
and timer again. This blinking shows that the internal clock go
wrong due to an interruption of the power supply. (Refer to
page 10.)
 Timer setting procedure
Before setting the timer, please adjust the clock. (Refer to "remote
controller preparation").
1. Press
.
on the remote controller display will blink.
2. Press
to choose timer operation.
(
)
The timer operation will change as follows:

Weekly timer

On timer
[
]
Off timer
[
]
Program timer
[
]
Sleep timer
3. Press
.
4. Set each timer operation.
For details, refer to the following instructions of each timer setting.
5. Press
to complete the timer setting.
Be close to the indoor unit.
• To cancel the timer setting during the procedure, press
again.
Upper and lower airfl ow
Conditions
Room temperature and set
temperature are different.
Room temperature is close
to set temperature, or the air
conditioner has operated for
1 hour.
-
Airfl ow temperature is high
Airfl ow temperature is low.
(During defrosting operation,
start of operation, etc.)
Enables you to set operation
schedules up to 4 setting for each
day of the week.
Starts the operation at your desired
time.
Stops the operation at your desired
time.
Operates as the combination of the
On timer and Off timer.
Supports your comfortable sleep
by moderating the air conditioner
operation gradually.
6.1. Weekly timer
 Setting details
1. Select Weekly timer in step 2 of "Timer setting procedure".
2. Press
to select the program number and the
(
)
day of the week.
Selected program number (1~4) and the day of the week will blink.
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
3. Press
.
4. Press
to choose the timer operation.
(
)
(Without a timer)
(On timer)
5. Press
.
* When you chose "Without a timer" in step 4, the setting display will
return to step 1.
6. Press
to set on time or off time.
(
)
7. Press
.
* When you chose "Off timer" in step 4, the setting display will return
to step 1.
8. Press
to set the temperature.
(
)
Temperature setting range
Auto, Cooling, or
18.0 to 30.0 °C
Dry mode:
*Even if you set to 10.0, 16.0-17.5 °C, the air
conditioner will run at 18.0 °C.
Heating mode:
10.0 or 16.0 to 30.0 °C
9. Press
.
The setting display will return to step 1.
10. Press
to complete the setting.
Be close to the indoor unit.
NOTES: [
] indicator on the indoor unit will not turn on even if
the setting is complete.
• If you want to return the previous step, press
• To check the schedule, use
timer settings in step 1.
To fi nish checking, press
• To deactivate the Weekly timer, press
shown on the remote controller display.
The indicator will disappear.
NOTES:
• The operation modes will be the same as the mode at the last time
operation was stopped, so Cooling → Heating → Cooling → Heating
type of operations cannot be set automatically.
• If you set the On timer and Off timer on the same time, the On timer
will work.
• If two On timers are set on the same time, the air conditioner will run
in the order of the program number.
• You cannot the Weekly timer and the other timers simultaneously.
If you use the On/Off timer, the Program timer, or the Sleep timer
while the Weekly timer is activated, the Weekly timer will be
deactivated.
In such a case, activate the Weekly timer after the other timer
fi nishes.
• If the wired remote controller (optional) is connected, this function is
restricted.
Program number
Day of the week
(Off timer)
.
to browse the Weekly
(
)
.
while
is
En-6