Specific Issues and Workarounds Concerning Solaris (Continued)
TABLE 7
CR ID
Description
6502204
Unexpected error messages may be displayed
on console on booting after CPU UE panic.
Example:
SUNW-MSG-ID: FMD-8000-11, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Tue Jan
2007
PLATFORM: SUNW,SPARC-Enterprise,
CSN: 2030636002, HOSTNAME: P2-DC1-
16-d0
6502750
Notification message for inserted or removed
card by PCI hot plug may not output.
6508432
Many correctable errors (CE) may occur, and
despite these are the correctable errors,
domain may panic.
6508434
The domain may panic when an additional
PCI-X card is installed or a PCI-X card is
replaced by using PCI hot plug.
6509337
s10s_u3 wanboot fails - The server returned
416: Requested Range Not Satisfiable.
6510779
On a large single domain configuration, the
system may incorrectly report very high load
average at times.
6510861
When Dual-Channel Ultra320 SCSI Card
(SE0X7SC2F, SE0X7SC2X) is mounted,
correctable errors(CE) occur and system may
panic.
6511374
Unexpected error messages may be displayed
on console after changing the system
configuration.
Example:
WARNING: Translation error source
/LSB0/B0/0, PA 3c000000000, target
/LSB0/B0/20000000
22
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • February 2008
Workaround
If you see unexpected messages, use the XSCF
command showdomainstatus(8) to check
system status on XSCF.
This bug has been fixed in Solaris 10 8/07.
9 20:45:08 JST
None available at this time.
This bug has been fixed in Solaris 10 8/07.
Set the following to /etc/system and then
reboot the domain:
set pcie:pcie_aer_ce_mask = 0x2001
This bug has been fixed in Solaris 10 8/07.
Do not insert a different type of PCI-X card on
the same PCI slot card by using PCI hot plug.
This bug has been fixed in Solaris 10 8/07.
This bug has been fixed in Solaris 10 8/07.
There is no workaround. Check for the
availability of a patch for this defect.
To mask these errors with Dual-Channel
Ultra320 SCSI Card (SE0X7SC2F, SE0X7SC2X),
add the following entry to the /etc/system
file and then reboot the system:
set pcie:pcie_aer_ce_mask = 0x31c1
This bug has been fixed in Solaris 10 8/07.
This message can be safely ignored.