Fujitsu ETERNUS AF650 Yapılandırma Kılavuzu - Sayfa 13
Depolama Fujitsu ETERNUS AF650 için çevrimiçi göz atın veya pdf Yapılandırma Kılavuzu indirin. Fujitsu ETERNUS AF650 18 sayfaları. Hybrid storage systems, all-flash arrays, power synchronized unit
Ayrıca Fujitsu ETERNUS AF650 için: Güvenlik Önlemleri (12 sayfalar)
FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series
2.3.
Hardware Layout
Protection against power supply problems or other disasters at the installation site requires that hardware units be physically installed in
different sites.
Accordingly, install duplicate hardware units in different buildings, on different floors, or in different racks.
Whether management servers are also installed at different sites depends on whether redundancy is used.
The following figure shows a layout in which management server redundancy is not used.
A
Business servers
Fibre Channel switch
Business drives
(using Storage Cluster for clustering)
ETERNUS AF/DX
The business servers, Fibre Channel switches, and storage systems are installed in different buildings, on different floors, or in different racks.
By clustering the business servers and the storage systems between different sites, business continuity can be maintained in the event of a
problem that affects the entire site.
Install the management server at a different site to prevent it from being affected by the problems in the business servers and storage
systems.
Copyright 2016-2017 FUJITSU LIMITED
C
Management server
Clustered
Clustered
Figure-6 Layout in which management server redundancy is not used
B
Business drives
(using Storage Cluster for clustering)
ETERNUS AF/DX
Legend
Page 13 of 18