Fujitsu ETERNUS DX60 S2 Yapılandırma Kılavuzu - Sayfa 11

Depolama Fujitsu ETERNUS DX60 S2 için çevrimiçi göz atın veya pdf Yapılandırma Kılavuzu indirin. Fujitsu ETERNUS DX60 S2 16 sayfaları. Server connection. (fibre channel) for aix
Ayrıca Fujitsu ETERNUS DX60 S2 için: Kullanıcı Kılavuzu (35 sayfalar), Kullanıcı Kılavuzu (42 sayfalar), Yapılandırma Kılavuzu (28 sayfalar), Kullanıcı Kılavuzu (14 sayfalar), Yapılandırma Kılavuzu (38 sayfalar), Donanım ve Yazılım Kurulum Kılavuzu (36 sayfalar)

Fujitsu ETERNUS DX60 S2 Yapılandırma Kılavuzu
Chapter 2
Setting Up the ETERNUS DX
2.1
Common Settings
OS
VMware ESX (*3)
PAN Manager
Citrix XenServer
Oracle VM Server for
x86
Oracle Linux
IBM SVC
For details on the firmware versions that support the Multipath Diagnostic Program, refer to "Multi-
*1:
path Diagnostic Program User's Guide".
An Oracle-brand Fibre Channel card driver may be used for Fujitsu Fibre Channel cards. To confirm
which driver should be used, check the "Notes" and "Fibre Channel Cards that Require an Oracle-brand
Driver" sections in "FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (Fibre Chan-
nel) for Oracle Solaris".
*2: Use of a PowerHA/HACMP cluster configuration only affects the setting for single path configurations
with FJspio.
*3: When connecting a Windows
shared between the VMware VCB Proxy server and VMware ESX server, the settings detailed in the
"VMware ESX" row of
2.1.3
Registering the WWNs of the Accessing Fibre Channel Cards or Converged Net-
work Adapter Cards (Setting FC Host)
Register the WWN of each Fibre Channel card or Converged Network Adapter card installed in the server that
will access the ETERNUS DX. At the same time, set the host response registered in
sion (Setting the Host Responses)" (page 9)
Registering the FC host WWNs and setting up LUN mappings (Host Affinities) as described elsewhere, allows
limits to be set on which servers are allowed to access which ETERNUS DX LUNs.
When a server-side Fibre Channel card or Converged Network Adapter card is replaced, the WWN of the
replacement Fibre Channel card or Converged Network Adapter card must be re-registered to the ETERNUS
DX.
Conditions
When one of the following condi-
tions applies
VMware vSphere
SAN Boot is configured with the
PRIMEQUEST 1000 series
For VMware Infrastructure 3
Common (required setting)
Common (required setting)
®
-based VMware VCB Proxy server to the ETERNUS DX, and the LUNs are
Table 2.5
should be used.
to accept these FC hosts (WWNs).
11
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
Copyright 2015 FUJITSU LIMITED
Parameter
Sense Data Conversion
Inquiry Standard Data Version
Sense Data Conversion
Sense Data Conversion
Byte-0 of Inquiry Response
Inquiry VPD ID Type
Reservation Conflict Response for
Test Unit Ready
Change Volume Mapping
Volume Capacity Expansion
Sense Data Conversion
"2.1.2 Sense Data Conver-
Setting value
Linux Recommended
(When not using
GRMPD)
Version 4
Linux Recommended
(When not using
GRMPD)
Linux Recommended
(When not using
GRMPD)
Custom
Type 1
Conflict
Report
Report
Linux Recommended
(When not using
GRMPD)
P3AM-3182-15ENZ0