Fujitsu ETERNUS DX8100 S2 Yapılandırma Kılavuzu - Sayfa 13
Depolama Fujitsu ETERNUS DX8100 S2 için çevrimiçi göz atın veya pdf Yapılandırma Kılavuzu indirin. Fujitsu ETERNUS DX8100 S2 28 sayfaları. Disk storage system settings
Ayrıca Fujitsu ETERNUS DX8100 S2 için: Kullanıcı Kılavuzu (35 sayfalar), Kullanıcı Kılavuzu (42 sayfalar), Yapılandırma Kılavuzu (15 sayfalar)
Chapter 4
Checking the Server Information
The server information registered in the ETERNUS DX should be checked.
A variety of commands are used to check the following server information.
iSCSI initiator name
•
Execute the following command:
iscsiutil -l
The iSCSI initiator name is displayed in the "Initiator Name" column.
Server-side LAN card IP address for connecting to the ETERNUS DX
•
Execute the following command:
ifconfig
Set this IP address if it is not already set.
Initiator CHAP Name
•
The Initiator CHAP Name is the user name for unidirectional CHAP authentication. Execute the following
command:
This is not required if CHAP authentication is not used.
iscsiutil -pD
The Initiator CHAP Name is displayed in the "Initiator CHAP Name" column of the applicable target infor-
mation.
CHAP Secret
•
The CHAP Secret is the password for unidirectional CHAP authentication. Execute the following command:
This is not required if CHAP authentication is not used.
iscsiutil -pD
The CHAP Secret is displayed in the "CHAP Secret" column of the applicable target information.
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI) for HP-UX
13
Copyright 2014 FUJITSU LIMITED
P3AM-3402-14ENZ0