AEG OKO_SANTO SUPER Kullanım Talimatları Kılavuzu - Sayfa 10
Buzdolabı AEG OKO_SANTO SUPER için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. AEG OKO_SANTO SUPER 32 sayfaları. Automatic refrigerator
Ayrıca AEG OKO_SANTO SUPER için: Kullanım Talimatları Kılavuzu (21 sayfalar), Kullanım Talimatları Kılavuzu (32 sayfalar), Kullanım Talimatları Kılavuzu (22 sayfalar)
Installation
Installation Location
The appliance should be installed in a well ventilated, dry room.
Energy use and efficient performance of the appliance is affected by
the ambient temperature.
The appliance should therefore
– not be exposed to direct sunlight;
– not be installed next to radiators, cookers or other sources of heat;
– only be installed at a location whose ambient temperature
corresponds to the climate classification, for which the appliance is
designed.
The climate classification can be found on the rating plate, which is
located at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for
each climate classification:
Climate classification
If installation next to a source of heat is unavoidable, the following
minimum clearances must be maintained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is
required between the cooker and the refrigeration appliance.
10
SN
N
ST
T
for an ambient temperature of
+10 to +32 °C
+16 to +32 °C
+18 to +38 °C
+18 to +43 °C
818 17 78-00/5