Overview of module's features in various regimes of operation
Definition of access rights using programming cards
Signalization of reading a card and releasing the door lock
Acoustic signalization of alarm situations
Changing the parameters of regimes of operation and alarm
regimes
Definition of access rights from the PC
Visualization of the regime of the reading modu le, recording
events in an archive in the PC, viewing and working with events
Controlling the output of the reading module directly from the PC

Technical parameters

Dimensions of the mother board
Power supply
Max. power input
ID technology
Max. number of access cards in the memory
Inputs
Output for door lock
Alarm output
Protective contact (tamper)
Typical reading distance
Communication channel
Alternative data output
Signalization
Working temperature
Max. relative humidity
Configurable operational parameters
Lock release duration
Acoustic signalization of lock releasing
Maximum duration of door opening
Duration of acoustic signalization of violation
Duration of acoustic signalization of door broken open
Duration of acoustic signalization of door open too long
nd
Function of the 2
Function
Parameter
input
autonomous
81 x 81 x 25 mm
10 ÷ 15 VDC
160 mA
EM Marin, 125kHz
748
2x logical, non-potential
1x relay switch contact 2 A / 24 V
Transistor output 5 V / 5 mA
Opto-electric
2 cm (in panel)
RS485 galvanic non-separated
WIEGAND (configurable)
Piezzo-buzzer + 3x LED (on the board)
-10 ÷ +40° C
75%, without condensation
Possible values
÷
0
255 s
Yes / no
÷
0
255 s
÷
0
255 s
÷
0
255 s
÷
0
255 s
Leaving button /
handle contact
4
Regime of operation
offline
Default value
7 s
Yes
30 s
30 s
30 s
0 s
Leaving button
online