Indesit I5G52G /UA Kullanım Talimatları Kılavuzu - Sayfa 9

Ocaklar Indesit I5G52G /UA için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Indesit I5G52G /UA 32 sayfaları. Cooker and oven

Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C and 1013 mbar- dry gas
**
Propane
***
Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
S S
I5G52G /UA
A
R
Thermal Power
By-Pass
kW (p.c.s.*)
1/100
Nominal Reduced
(mm)
3.00
0.7
41
1.90
0.4
30
1.00
0.4
30
P.C.S. = 50,37 MJ/Kg
3
Liquid Gas
Nozzle
Flow*
1/100
g/h
(mm)
***
**
87
218
214
70
138
136
52
73
71
28-30
37
20
25
35
45
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
Useful
measurements
relating to the oven
compartment
Power supply voltage
and frequency
Energy Label
Burners
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
Natural Gas
Nozzle
Flow*
Nozzle
1/100
l/h
1/100
(mm)
(mm)
128
286
143
104
181
118
76
95
80
20
13
17
6,5
25
18
340x 410x 424 mm
60 l
width 42 cm
depth 44 cm
height 23 cm
see data plate
Declared energy consumption for
Natural convection Class
Heating mode:
Convection
Energy consumption for Forced
convection heating mode:
Fan assisted
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments - 2002/96/EC.
1275/2008 (Stand-by/ Off mode)
GB
Flow*
l/h
286
181
95
9