Indesit K3G11/G Kurulum ve Kullanım Kılavuzu için Talimatlar - Sayfa 6
Ocaklar Indesit K3G11/G için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu için Talimatlar indirin. Indesit K3G11/G 17 sayfaları. Cooker with electric oven
Ayrıca Indesit K3G11/G için: Kullanım Talimatları Kılavuzu (12 sayfalar)
Adapting the cooker to different types of gas
In order to adapt the cooker to a different type of gas with
respect to the gas for which it was produced (indicated on
the label attached to the lid), follow these steps:
a) replace the hose holder mounted on the appliance with
that supplied in the bag of "cooker accessories".
Important: the hose holder for liquid gas is marked 8, the
hose holder for methane gas is marked 13. Always fit the
sealing gasket.
b) Replacing the burner nozzles on the hob:
•
remove the grids and slide the burners from their
housings;
•
unscrew the nozzles using a 7 mm socket spanner,
and replace them with nozzles for the new type of gas
(see table 1 "Burner and nozzle characteristics").
•
replace all the components by repeating the steps in
reverse order.
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
Burner and nozzle characteristics
Thermal Power
By-Pass
kW (p.c.s.*)
1/100
Nominal
Reduced
(mm)
3.00
0.7
41
1.90
0.4
30
1.00
0.4
30
3
c) Minimum regulation of the hob burners:
•
turn the tap to minimum;
•
remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: in the case of liquid gas, the regulation screw
must be screwed in to the bottom.
•
check that the flame does not turn off when you turn
the tap quickly from high to low.
d Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
"regulators for channelled gas".
Liquid Gas
Nozzle
Flow*
1/100
g/h
(mm)
***
86
218
70
138
50
73
28-30
20
35
S S
A
R
K3G11/G
6
Natural Gas
Nozzle
Flow*
1/100
l/h
**
(mm)
214
116
286
136
106
181
71
79
95
37
20
25
17
45
25