Indesit KN3E11/EX Kullanım Talimatları Kılavuzu - Sayfa 5
Ocaklar Indesit KN3E11/EX için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Indesit KN3E11/EX 21 sayfaları. Cooker and oven
Installation
! Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and
operation of the appliance.
! Please keep these operating instructions for future
reference. Make sure that the instructions are kept with
the appliance if it is sold, given away or moved.
! The appliance must be installed by a qualified
professional according to the instructions provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.
Positioning and levelling
! It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.
! Make sure that the wall in contact with the beck of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).
To install the appliance correctly:
• Place it in the kitchen, dining room or the bed-sit (not
in the bathroom).
• If the top of the hob is higher than the cupboards,
the appliance must be installed at least 200 mm away
from them.
HOOD
600
Min.
mm.
• Do not position blinds behind the cooker or less than
200 mm away from its sides.
• Any hoods must be installed according to the
instructions listed in the relevant operating manual.
•
If the cooker is
installed underneath a
wall cabinet, there must
be a minimum distance
of 420 mm between this
cabinet and the top of
the hob.
This distance should be
increased to 700 mm
if the wall cabinets are
flammable (see gure).
Levelling
If it is necessary to level the
appliance, screw the adjustable
feet into the places provided on
each corner of the base of the
cooker (see gure).
The legs* fit into the slots on the
underside of the base of the
cooker.
Electrical connection
Fitting the power supply cable
The cable should be suited to the type of electrical
connection used, according to the following connection
diagram:
400 3N
H05RR-F 5x2.5 CEI-UNEL 35363
H05VV-F 5x2.5 CEI-UNEL 35746
400V 2N
H05RR-F 4x4 CEI-UNEL 35363
H05VV-F 4x4 CEI-UNEL 35746
230V
H05RR-F 3x4 CEI-UNEL 35363
H05VV-F 3X4 CEI-UNEL 35746
To install the power supply cable correctly:
1. Loosen the screw V in the terminal board and pull
the cover to open it (see gure).
V
3
2
1
B
A
N
1
2
3
4
5
T
R
S
N
1
2
3
4
5
R
S
N
3
4
5
1
2
R
N
2. Position the
connection supports A
(see gure) according
to the connection
diagram shown above.
The terminal board is
designed for single-
phase 230 V connection:
terminals 1, 2 and 3
are connected to each
other; jumper 4-5 is
located in the lower area
of the terminal board.
3. Position the wires
5
GB