Indesit KP 9508 E/G Kurulum ve Kullanım Kılavuzu - Sayfa 12

Ocaklar Indesit KP 9508 E/G için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Indesit KP 9508 E/G 17 sayfaları. Cooker with electric oven

Indesit KP 9508 E/G Kurulum ve Kullanım Kılavuzu
must be fitted between the appliance and the mains supply
outlet. The yellow-green earth wire must not be interrupted
by the switch. The supply cable must be in such a position
that no part of it can reach a temperature of 50 °C above
room temperature. Do not use adapters or shunts as they
could cause heating or burning. Before connecting to the
power supply, make sure that:
• the limiter valve and the domestic system can withstand
the load from the appliance (see rating plate);
• the supply system is efficiently earthed according to
standards and laws in force;
• the socket or double-pole switch are easily accessible when
the appliance is installed.
FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF ALL
LIABILITY.
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection
heating mode:
Convection
Declared energy consumption for Forced convection Class
heating mode:
Fan assisted (mod. KP 59 MS)
BURNERS AND NOZZLES SPECIFICATIONS
Table 1
Burner
Fast
(Large) (R)
Semi Fast
(Medium) (S)
Auxiliary
(Small) (A)
Triple Crown (TC)
Supply pressures
* At 15°C and 1013 mbar-dry gas
Propane G31
Butane G30 H.s. = 49,47 MJ/kg
Methane G20
IE
GB
ELECTRICAL CONNECTION

TECHNICAL SPECIFICATIONS

Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nom.
Red.
100
3.00
0.7
75
1.65
0.4
55
1.00
0.4
130
3.25
1.3
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
H.s. = 50,37 MJ/kg
H.s. = 37,78 MJ/m 3
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked "E" or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked "L" or coloured
Red.
Connect the Blue wire to the terminal marked "N" or coloured
Black.
Replacing the cable
Use a rubber cable of the type H05VV-F with a suitable cross
section 3 x 1.5 mm².
The yellow-green earth wire must be 2-3 cm longer than the
other wires.
This appliance conforms with the following European Economic
Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent modifications;
-
89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and
subsequent modifications;
-
90/396/EEC of 29/06/90 (Gas) and subsequent modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.
Oven accessories which may come into contact with food
are make in materials complying to what is laid down in
EEC Directive 89/109 of 21.12.88 and national regulations
in force.
Liquid Gas
By-pa-
Nozzle
Flow*
ss
1/100
g/h
1/100
(mm)
(mm)
G30/31
40
86
218
30
64
120
30
50
73
57
91
236
28-30
20
35
10
- Earth
- Neutral
- Live
Natural Gas
Nozzler
Flow*
1/100
l/h
(mm)
116
286
96
157
71
95
124
309
20
17
25