Indesit TIL642 Servis Kılavuzu - Sayfa 25
Hob Indesit TIL642 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Indesit TIL642 29 sayfaları. Hobs 2006
5.4. MEASUREMENTS:
Precautions before working on the appliance:
Check voltage range OK: 190-240V- in certain cases the appliance will not function at 200V - the
check is aimed at identifying 210 V at which the appliance must function; the fault is indicated by
fl ashing of the display / power indicator lights
Check for possible burns on the connections
Check of wiring and fl at connection cable between generator and control PCB for possible cuts
due to external causes
Check rated voltage on generator power supply from fi lter (220V)
Voltage measurement 12V DC at two ends
Voltage measurement 5V DC on second from left and last
Service Manual
Hobs - 2006
1. NTC on generator approximately 100 K (generates
a fault anyway and inhibits operation of the plate
assembled with the relative NTC)
2. Voltage regulator: 12 V detected between central and
left and 5V between central and right: UNDERVOL-
TAGE CONDITIONS!!!
3. IGBT: there are three contacts on this device: a mea-
surement taken between any two of them must not
return a value of 0 –
THIS MEASUREMENT MUST BE PERFORMED
WITH THE Hob DISCONNECTED FROM THE
POWER SUPPLY
IGBT / power transistor static check
Edition
2006.03.13
G
Language
English
B
25