AEG CHDF 6260 Çalıştırma ve Kurulum Talimatları - Sayfa 3

Havalandırma Davlumbazı AEG CHDF 6260 için çevrimiçi göz atın veya pdf Çalıştırma ve Kurulum Talimatları indirin. AEG CHDF 6260 21 sayfaları. Electrolux cooktop user manual
Ayrıca AEG CHDF 6260 için: Çalıştırma ve Kurulum Talimatları (21 sayfalar), Kullanım ve Kurulum Kılavuzu (21 sayfalar), Kullanım ve Kurulum Kılavuzu (22 sayfalar), Çalıştırma ve Kurulum Talimatları (23 sayfalar), Çalıştırma ve Kurulum Talimatları (22 sayfalar)

AEG CHDF 6260 Çalıştırma ve Kurulum Talimatları

Safety warnings

for user

• Always cover lighted elements, to prevent excess heat from
damaging the appliance. In the case of oil, gas and coal fired
cookers it is essential to avoid open flames.
• Also, when frying, keep the deep frying pan on the cooker top/
cooker under careful control.
• The hot oil in the frying pan might ignite due to overheating.
• The risk of self-ignition increases when the oil being used is dirty.
• It is extremely important to note that overheating can cause a fire.
• Never carry out any flambé cooking under the hood.
• Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch
off the automatic circuit breaker).
• It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, causing a fire hazard.

for kitchen unit installer

• When used as an extractor unit, the hood must be fitted with a
150mm diameter hose.
• When installing the hood, make sure you respect the following
minimum distance from the top edge of the cooking hob/ring
surfaces:
electric cookers
gas cookers
coal and oil cookers
• The national decree on fuel-burning systems specifies a maximum
depression of 0.04 bar in such rooms.
• The air outlet must not be connected to chimney flues or combus-
tion gas ducts. The air outlet must under no circumstances be
connected to ventilation ducts for rooms in which fuel-burning
appliances are installed.
• It is advisable to apply for authorization from the relevant controlling
authority when connecting the outlet to an unused chimney flue or
combustion gas duct.
The air outlet installation must comply with the regulations laid down
by the relevant authorities.
465 mm
650 mm
700 mm min.
69