22. DO NOT connect the outlet of the shower to any tap, control valve,
trigger operated handset or showerhead other than those specified
for use with this shower as the outlet acts as a vent for the tank
body. Only Kohler Mira recommended accessories should be used.
23. DO NOT perform any unspecified modifications, or drill or cut holes
in the product other than instructed by this guide. When servicing
only use genuine Kohler Mira replacement parts.
24. DO NOT connect this shower to a Waste Water Heat Recovery
System as this may cause unstable or scalding temperatures to
be delivered from the shower head.
25. Always check the water temperature is safe before entering the
shower.
26. The water supplies to this product must be isolated if the product is
not to be used for a long period of time. If the product or pipework
is at risk of freezing during this period they should also be drained
of water.
27. If the shower is dismantled during installation or servicing then,
upon completion, an inspection must be made to ensure all
electrical connections are tight and that there are no leaks.
28. This appliance is intended to be permanently connected to the
water mains and not connected by a hose set.
29. The water inlet of this appliance shall not be connected to a water
supply obtained from any other water heating system.
30. Warning! This appliance is not to be used to provide a potable
water supply.
31. Maximum Static Pressure is 1000 kPa (10 bar).
32. Minimum Dynamic Pressure is 70 kPa (0.7 bar) 9.0 kW and
9.8 kW.
5