Route the tower cable into the large hole in the back of the
mounting frame. Snap the modular plug on the end of the
tower cable into the left jack of the control box. Install the
large strain relief bushing over the tower cable, and insert
it into the large mounting frame hole.
TE:
NO
National Electrical Code requires that you
permanently separate the high- and low-voltage cables.
Route the waterfall light wires through the small hole in the
back of the mounting frame. With the pump access panel
removed, connect the waterfall light wire connectors to
the transformer terminals – white to white; black to black.
Install the small strain relief bushing over the waterfall light
wires, and insert it into the small mounting frame hole.
AB
116290-2-
Large
Strain
Relief
Mounting Frame
Control Box
From
Waterfall
Light
Small
Strain
Relief
Bushing
20
Tower Cable
Mounting Frame
Small
Hole
Transformer
Snap
To Control Box