Machine settings

1. Unscrew cover above the bulb (this can be found directly behind the loading aperture,
at the top; refer to "Description of machine" section.)
2. Replace defective bulb.
3. Screw cover back down.
Check the correct positioning of o-ring gasket before screwing back the door light cover.
Do not operate the dryer when missing o-ring gasket on door light cover.
WARNING!
For safety reasons, the cover must be screwed down tightly. If this is not done, the dryer
must not be operated.
Machine settings
Buzzer permanent on/off
Water hardness
Water contains, a variable quantity of
limestone and mineral salts of which
quantities vary according to geograph-
ical locations thus varying its conduc-
tivity values.
Relevant variations of the conductivity
of the water compared to those prefixed
by the factory could slightly influence
the residual humidity of the laundry at
the end of the cycle. Your dryer allows
you to regulate the sensitivity of the
drying sensor based on conductivity
values of the water.
Setting
Implementation
1. Turn the programme selector to any programme.
2. Press simultaneously the DELICATE (1) and LONG
ANTI-CREASE (2) buttons and hold down for approx.
5 seconds.
– diode above BUZZER button (3) starts lighting -
buzzer permanently on.
– lighting diode comes off - buzzer permanently off.
3. The buzzer is by default always off. You can use the
BUZZER button (3) to activate or deactivate sound
but the machine does not memorize your selection.
1. Turn the programme selector to any programme.
2. Press simultaneously the DELICATE (1) and TIME (4)
buttons and hold down for approx. 5 seconds. The
current setting is on the display:
low conductivity <300 μS/cm
medium conductivity 300-600 μS/cm
high conductivity >600 μS/cm
3. Press the START PAUSE button (5) sequentially until
you set desired level.
4. To memorize setting press simultaneously the DELI-
CATE (1) and TIME (4) buttons or turn knob to OFF
position