Kohler URBANITY 25717T-9 Kurulum Talimatları - Sayfa 3

Banyo Armatürleri Kohler URBANITY 25717T-9 için çevrimiçi göz atın veya pdf Kurulum Talimatları indirin. Kohler URBANITY 25717T-9 4 sayfaları. Recessed thermostatic dual shower faucet-multifunction showerhead

Kohler URBANITY 25717T-9 Kurulum Talimatları
43
42
44
48
46
Drain notch
47
45
INSTALLATION CHECKOUT
Number 37
49
53
52
50
51
Indicator line
Upward
horizontally
27
Spindle
CARE AND MAINTENANCE
Filter
25
26
24
1418848-2A-C
Install the Bracket
Determine a suitable location on the finished wall to install bracket.
Ensure it should avoid buried cables and pipes in the wall.
Mark the mounting holes of the base(42) on the wall according to
the dimension. Drill two holes in the finished wall, the holes should
match the anchors(43) and be vertical. Install the anchors. Tighten
the screws(44) to fix the base on the finished wall. NOTE: The
direction of the base is shown in the figure.
Loosen the screw(47) in the bracket(46) bottom with hex wrench
(45) until the bracket can be installed into the base. Slide the
escutcheon(48) onto the bracket. Apply a ring of plumbers putty or
other sealants around the underside of the escutcheon. Move the
bracket onto the base until it is against the finished wall and
confirm the drain notch and screw hole are pointed down. Tighten
the screw(47) with hex wrench to fix the bracket and escutcheon
on the finished wall. Remove any excess putty or sealant.
Ensure that all connections are tight, the switch buttons are not
turned on. Turn on the water supply. Run water through the valve.
Check for leakage. Repair as needed.
Press the buttons separately. Check whether all connections and
water flow are well. Shut off the faucet.
Verification and Setting
Make sure that the water feeds of the faucet have reach the
highest temperature by running the water sufficiently. When the
number 37 on the temperature handle(49) is upward vertically,
the temperature of the water should be within a range of 36ºC and
38ºC, as measured by a thermometer. If not, the installer can
adjust the setting. Proceed with the setting as follows:
Remove the plug(51). Take out the screw(50) with 2.5mm hex
wrench(27) to uninstall the temperature handle. Remove the
screw(52) with a screwdriver. Remove the adapter spline(53).
Under the normal condition of water flow, slowly turn the
temperature selector(Always in the same direction) from the cold
water position until water temperature reaches 37ºC. If the
temperature goes over 37ºC, go back to the "cold" setting and
reset it. When the temperature is stable, do not turn the cartridge
spindle. Install the adapter spline. Ensure the indicator line on the
adapter spline align with the indicator line on the stopper. Tighten
the screw(52) with a screwdriver. Install the temperature handle.
Ensure the number 37 on the temperature handle is upward
vertically(After assembly, it could not be turned counter-clockwise
if not pushing the button). Tighten the screw(50) with 2.5mm hex
wrench. Insert the plug(51).
Clear the Filter
The filters can protect the faucet, but it may get obstructed and
reduce water flow after a long time of use. If this happens, , turn
off the water supply.
Take out the plugs(26). Unscrew two screws(25) with 3mm hex
wrench(24) to uninstall faucet. Take out the filters by hand. Clean
the filters by soaking them in warm vinegar. Reinstall in turn.
INSTALLATION
1
5
4
2
Connect the Pipes
As figure 1 shown, apply enough tape or suitable sealant on threads of the showerhead outlet tubes(1, not provided) and
two connections(2). Install the G1/2˝ hot and cold supply pipes into two connections, and make sure the hot supply should
be installed to the side with red dot of the inlet assembly(3). Connect one end of the showerhead outlet tubes with the
connector(4), and connect the other end with shower arm base(5).
As figure 2 shown, ensure the showerhead outlet tubes(1) are connected correctly with shower arm base(5).
Install the Inlet Assembly
During installation, please do not remove the protectors(6, 7) until instructed to do.
Select a location in the vertical wall to install the inlet assembly(3) according to rough-in dimensions. As figure 2 shown,
make sure the protectors(6, 7) face front and the inlet assembly with red dot is on the left side. NOTE: Make sure the
centerline of the inlet assembly is vertical to the wall, the upper surfaces of the protectors is horizontal.
3
11
9
5
Install the Shower Arm Base
During installation, please do not remove the protector(8) until instructed to do.
Select a location in the vertical wall to install the base(5) according to rough-in dimensions. Make a suitable hole in the wall.
As figure 3 shown, drill three holes(Ø8) as expansion screws'(9) diameter and base position in the wall. The center line
of two horizontal holes should be horizontal. Install the expansion screws. Secure the base, washers(11) and locking
gaskets(12) on the wall with the nuts(10).
As figure 4 shown, ensure the bottom of the protector(8) is horizontal by level.
6
1418848-2A-C
2
5
1 (Not provided)
1
Kloud burst
3
Red dot
2
Hot
Cold
4
12
10
Ø8
8
82
11
12
10
Level
1
Katalyst rain
7
3
Cold
6
Hot
6
Level
8
8
3