Installation Instructions
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
WARNING: Risk of electric shock. Connect only to a circuit protected by a Ground-Fault
Circuit-Interrupter (GFCI)*.
Install to permit access for servicing.
A pressure wire connector marked "Earth/Ground" is provided within the wiring compartment. To reduce
the risk of electric shock, connect this connector to the grounding terminal of your electric service or supply
panel with copper wire equivalent in size to the circuit conductor supplying this equipment.
Pressure wire connectors are provided on the exterior of the junction box or control within this unit to permit
connection of a bonding conductor between this unit and all other exposed metal in the vicinity, as needed to
comply with local requirements.
An equipment grounding terminal is provided in the field wiring compartment. To reduce the risk of electric
shock, this terminal must be connected to the grounding means provided in the electric supply panel with a
conductor equivalent in size to the circuit conductors supplying this equipment.
Grounding is required. The unit should be installed by a qualified service representative, and grounded.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation.
WARNING: Risk of electric shock. A qualified electrician should make all electrical connections.
WARNING: Risk of electric shock. Disconnect power before servicing.
NOTICE: Follow all local plumbing and electrical codes. In Canada, install this unit in accordance with
the Canadian Electrical Code, Part 1.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Product Information
Electrical Requirements
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD). The GFCI or RCD protects against line-to-ground shock hazards. Use a 120 V, 15A, 50/60 Hz
dedicated service for the bath with airjets.
The electrical rating of the bath is printed on a label near the blower motor. You can also find the electrical
requirements from the Installation Guide packed with the bath in the Product Information section.
If the blower supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Product Notices
WARNING: Risk of personal injury or property damage. Unauthorized modification may cause
unsafe operation or affect performance of the bath. Do not relocate the blower motor, or make other
modifications to the bath system in the absence of kit or other published instructions, as this could
adversely affect the performance and safe operation of the product. Kohler Co. shall not be liable
under its warranty or otherwise for personal injury or damage caused by any such unauthorized
modification. Refer to the "Prepare the Blower (Remote Site)" section for blower motor relocation
requirements, recommendations, and section coverage information.
NOTICE: This product contains an automatic water purge mode that turns the blower on for 2 minutes
approximately 30 minutes after the unit is turned off and drained.
1220597-2-A
2
Kohler Co.