Cross Pattern Fine Signal
Tolerance
Fine Peak Signal Difference
Threshold
Fine Peaking Cycles
Fine Peaking Maximum Cycles
Fine Peaking Mode
Plateau Peaking Fine Azimuth
Velocity
Plateau Peaking Fine Elevation
Velocity
Step Pattern Fine Azimuth
Velocity
Step Pattern Fine Elevation
Velocity
Step Pattern Fine Peaking
Azimuth Step
Step Pattern Fine Peaking
Elevation Step
3.4. Feed Configuration Items
No feed configuration items are available for this module.
AvL Technologies
4
Float
0 – 1000
4
Float
0.1 – 100
4
Float
4
Float
CrossPattern/
4
Choice
StepPattern/
PlateauPeaking
4
Float
0.02 – 0.5
4
Float
0.02 – 0.5
4
Float
0.02 – 0.5
4
Float
0.01 – 0.5
4
Float
0.02 – 0.5
4
Float
0.01 – 0.5
| Proprietary – Content is Subject to Change without Notice
Step Track Hold Tracking
Signal degradation amount before a scan stops
The amount of signal difference between peaking
iterations that will satisfy the system as the signal is
0 – 100
Number of cycles to complete for fine peaking
Maximum number of cycles to complete for fine
1 – 100
Selection of the peaking method to use for fine
Azimuth velocity in degrees/sec for fine peaking
Elevation velocity in degrees/sec for fine peaking
Azimuth velocity in degrees/sec for fine peaking
Elevation velocity in degrees/sec for fine peaking
Width in degrees to scan during a fine step pattern
Height in degrees to scan during a fine step pattern
peaked
peaking stops
peaking routines
peaking function
peaking function
7