Dexter Laundry DRC55 Series Kullanım Kılavuzu - Sayfa 5
Kurutucu Dexter Laundry DRC55 Series için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Dexter Laundry DRC55 Series 12 sayfaları. Dexter drc55 series dryers (25kg capacity)
III. Back
IV. Front
V. Top
VI. Floor
*Units may be installed in direct contact with an adjacent dryer, providing allowance is made for
opening upper and lower service doors.
Refer to installation label attached to the inside surface of the upper service door of the dryer for
other installation information.
18 in. (450 mm) clearance is necessary behind the belt guard to allow
servicing and maintenance.
48 in. (1200 mm) to allow use of dryer.
Refer to figure labeled "Vertical Clearance Dimensions".
AB. 0 clearance at the top, 1 in. (25 mm) back from the front.
However 1/4 in. (6 mm) clearance is required to allow opening the upper
service door.
CD. A 4 in. (100 mm) clearance is required at the top between 1 in. (25
mm) and 4 in. (100 mm) from front.
E. A 10" (250 mm) clearance is required from top at all other points.
This unit may be installed upon a combustible floor.
-5-
3.