FUNCTION
The Aqua Exclusive Drum Filter C-25 EVO is an modern and very effective all in one filter
system. Connecting separate filter equipment is a thing of the past. The C-25 EVO is made for
(koi) ponds, (large) aquariums and fish farms.
The filter consists of 3 main elements:
1. Rotary Drum Filter - RDF (Mechanical filter )
2. Moving Bed Bio Chamber (Bio Filter)
3. High Output UV-C system (Disinfection).
This filter cleans itself when necessary, everything works fully automatic.
The system is equipped with a 70 micron filter panel and has two 4"/110mm inlets and one
4"/110mm outlet. This ensures a water flow of 5.250 Gallons (20.000 Liter) per hour. For opti-
mal functioning of your bio filter, we recommended 2.650 Gallons (10.000 Liters) per hour.
SAFETY WARNINGS
The device may only be connected to an electrical installation that meets the legal stan-
dards. A residual-current device (30 mA) and earthed wall socket are required. If in doubt,
consult a qualified installer.
Both the Drum Filter and the control box must be installed in a dry, sheltered place. Not in
direct sunlight.
Keep the power plug free from moisture. Prevent water from running along the power
lead into the socket.
The device is suitable for fresh water.
The device is suitable for water temperatures of 4 to 40 °C. If exposed to temperatures
outside these limits, the device must be fully isolated from the water circuit.
Before commissioning, check the entire device, mains lead and plug for damage. If dam-
age is found, the device may not be used. Have the damage assessed by the dealer.
The device may only be switched on when there is sufficient water flow.
When opening the lid/maintenance cover the power to the device/control box must al-
ways be switched off.
The UV-C lamp may still be hot up to ten minutes after it is switched off.
Read the entire manual before use/installation of the system!
2
Safety & Requirements
C-25 EVO OWNER'S MANUAL