A.J.Antunes 9100533 Kullanıcı El Kitabı - Sayfa 8
Ticari Gıda Ekipmanları A.J.Antunes 9100533 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. A.J.Antunes 9100533 16 sayfaları. Steamer display cabinet
STEAMER DISPLAY CABINET SDC-500
Operating Instructions
1. Open the Front Door.
2. Remove the Diffuser and Shelves only if pouring water
directly into the unit instead of the Water Tube.
3. Pour 7 quarts (5.6 liters) of clean tap water into the
Water Pan (Figure 6).
NOTE: The front Water Tube is also used to indicate the
unit water level. Water should always be visible in the
tube and should not exceed the "MAX" line (Figure 3)
(Not Included)
Water can be poured
into the unit from the
front door or using the
Water Tube as shown
Figure 6. Filling SDC-500 with Water
CAUTION
Do NOT pour water hotter than 120°F (48°C) into a cold
unit. Resulting steam may cause injury.
4. Reinstall the Diffuser and Shelves. Then load product
into the unit and close the Front Door.
5. Turn the unit on. During the initial warm-up period, the
unit will display the following sequence of codes:
a. "8888" for one second.
b. "CH-1" for one second.
c. The unit's Setpoint Temperature for one second.
d. "CH-1" for one second.
e. The unit's Setpoint Temperature.
f. The unit's actual cabinet temperature.
6. To remove product from the unit, open the Front Door
and use tongs or a similar utensil to lift the product out.
NOTE: Keep the Front Door closed unless adding or
removing product.
WARNING
Keep face away from cover and opening when remov-
ing product. Steam can escape and cause injury.
OPERATION
Funnel
LIN
E
LIN
E
PO
WE
R
Setpoint Temperature
Your SDC-500 is factory programmed to operate at a specific
temperature called the Setpoint Temperature. To change the
Setpoint Temperature:
1. Press and hold the ▲ and ▼ buttons until the display
flashes.
2. Release the buttons.
3. Press ▲ or ▼ to raise or lower the Setpoint
Temperature.
4. Release the buttons. The unit saves the new Setpoint
Temperature into memory.
NOTE The SDC-500 has an adjustable temperature range
of 150°F–180°F (66°C–82°C).
NOTE: To change the display between Fahrenheit and
Celsius, press and hold the Temp Scale button for 2–3
seconds and release.
FULL
LINE
REFILL
LINE
PUSH TO RESET
Figure 7. Hi-Limit Reset Button
Hi-Limit Reset Button
A hi-limit thermostat turns off power to the unit if it overheats.
This may happen if the unit runs out of water. To reset this
thermostat:
1. Turn the unit off. Allow it to cool for 10 to 15 minutes.
2. Check the water level. Add water if needed.
3. Press the reset button located on the front of the unit
(Figure 7).
4. Restart the unit.
If the unit requires continuous resetting, contact your
Authorized Service Agency.
8
LINE
P/N 1010968 Rev. E 12/14