(A) INTRODUCTION
Aqua Flo AQUV UV systems make water safe to drink by instantly destroying pathogenic
bacteria (such as coliforms, E. coli, viruses etc.). These systems utilize the proven
disinfection properties of ultraviolet light (UV) emitted at 254 nm wavelength. UV
systems are used by many municipalities in North America and around the world as a
primary disinfectant as it is a natural, non-chemical, environmentally safe technique
that does not form any harmful disinfection by-products.
HOW THE AQUA FLO AQUV UV WATER DISINFECTION SYSTEM WORKS
Your Aqua Flo AQUV UV system consists of a low-pressure UV lamp enclosed in a
transparent quartz dome, housed in a stainless steel disinfection chamber. As untreated
water enters the chamber from one end, pathogenic microorganisms in the water are
exposed to and instantly destroyed by ultraviolet light emitted by a specially engineered
UV lamp. Treated water flows out of the chamber and is ready for consumption.
See Fig. 1.
(B) SAFETY GUIDELINES
This is the safety alert symbol. When you see this symbol, look for one of the following signal words:
Indicates a hazardous situation which, if not avoided, will result in death or serious injury
DANGER
and/or property loss or damage.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury and/
WARNING
or property loss or damage.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury
CAUTION
and/or property loss or damage.
NOTICE
Indicates important information, that if not followed, may result in damage to the equipment.
Contains mercury
Hg
Lamp contains mercury (Hg).
Dispose or recycle in accordance with applicable laws.
For information on safe handling procedures and safe disposal and recycling, consult :
Diverting Mercury
BALLAST
110 V AC
Fig. 1.
Management of
Lamps Containing
Mercury:
SAFE WATER
OUT
QUARTZ DOME
UV LAMP
UNTREATED WATER IN