DeZurik ANSI/AWWA C540 Talimatlar - Sayfa 6

Endüstriyel Ekipmanlar DeZurik ANSI/AWWA C540 için çevrimiçi göz atın veya pdf Talimatlar indirin. DeZurik ANSI/AWWA C540 8 sayfaları. Ansi/awwa pneumatic cylinder for g-series actuators
Ayrıca DeZurik ANSI/AWWA C540 için: Talimatlar Kılavuzu (9 sayfalar)

DeZURIK
ANSI/AWWA C540 Hydrualic Cylinder for G-Series Actuators
Reassembly
(continued)
2. Attach the isolation plate, then the cylinder head to the actuator. See Figure 2.
3. Carefully install the rack rod and piston rod.
4. Eccentric valves: Install the spacer, spring washers and nuts on the rack rod. See Table B and
Figure 4 for spring washer arrangement.
All other valves: Install the jam nuts on the rack rod.
5. Eccentric valves: Tighten the nut until the spring washers are completely compressed, and then
back off until they return to their normal uncompressed shape.
All other valves: Tighten the first nut.
6. Tighten the second nut.
7. Install the extension cap.
8. Put the piston on the piston rod and install the nut.
9. Remove the piston seal and its O-ring. Clean the O-ring, seal and groove. Lubricate the O-ring and
seal and install them. Use new O-ring and seal if necessary.
10. Lubricate the cylinder tube.
11. Carefully slide the cylinder over the piston. The seal and the cylinder must be well lubricated.
12. On 6-inch and larger cylinders, remove one or two of the tie rods.
D10296
Figure 2—Cylinder Parts Location
Page 6
March 2017