Aqua Lung apeks XTX 200(FSR) Kullanıcı El Kitabı - Sayfa 13
Kontrolör Aqua Lung apeks XTX 200(FSR) için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Aqua Lung apeks XTX 200(FSR) 20 sayfaları.
Regulator Owner's Manual
............................................................................................
External Second Stage Adjustments
External adjustment features offer many advantages, including
the ability to adjust your second stage regulator's sensitivity as
your diving conditions change. This allows you to maintain peak
performance throughout every dive, or to desensitise your regulator's
opening effort at times when you are not breathing from it.
Integrated Venturi Switch
Apeks second stages are equipped with a diver controllable venturi
system. This system is known as the integrated venturi system (IVS)
switch or Reversible Venturi System (RVS) on the XTX range of
second stage regulators. This switch allows the diver to control the
venturi assist to reduce sensitivity to free flow at the surface and
provide the maximum airflow at depth.
Whilst diving, set the switch to plus (+) to achieve maximum venturi
assistance for easier breathing.
To prevent the second stage from free-flowing, however, you should
set the IVS/RVS to the MIN(–) setting during entry or while swimming
on the surface.
Note: Egress Second
Stages (not
shown) do
not include
an inter-
grated venturi
Switch.
CAUTION: Do not use
mouthpiece insertion type
Octopus holders. The
internal venturi deflector may
become dislodged.
+
13