Aqua Lung Legend LX Second Stage Teknik Bakım Kılavuzu - Sayfa 13

Kontrolör Aqua Lung Legend LX Second Stage için çevrimiçi göz atın veya pdf Teknik Bakım Kılavuzu indirin. Aqua Lung Legend LX Second Stage 18 sayfaları.

Aqua Lung Legend LX Second Stage Teknik Bakım Kılavuzu
PART NO.
DESCRIPTION
111610
I.P. test gauge
944022
O-ring tool, set
129001
Retaining Ring Tool
109436
Seat extract/install tool
100190
Inline Adjustment Tool
n/a
Torque wrench, inch-pound
n/a
11/16" crows-foot
n/a
Medium blade screwdriver
n/a
11/16" wrench (x2)
n/a
4mm hex wrench
n/a
1/16" wooden dowel
Table 2 - Recommended Tool List
APPLICATION
Intermediate pressure testing
O-ring removal and installation
Retaining ring removal and installation
Crown removal and installation
2nd-stage adjustment
Retaining nut, hose
Retaining nut, hose (used with torque wrench)
Crown
Retaining nut, hose
Adjustment Screw
Shuttle valve removal
13