Aqua Medic Marin Control Digital Kullanım Kılavuzu - Sayfa 5
Ölçüm Cihazları Aqua Medic Marin Control Digital için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Aqua Medic Marin Control Digital 5 sayfaları. Digital meter for the measurement of temperature, salinity and specific gravity in saltwater aquariums
6. Wait 10 seconds for the Specific Gravity to stabilize and read results.
7. You may press the ("HOLD") button at anytime to "lock" the measurement so you do not have to keep the probe
submerged in the water to read the measurement value. Press again to "unlock" and test again.
8. Press ("ON/OFF") when you are finished. Your Battery Saving Function will automatically shut off your tester is no
activity, is detected within 1 minute.
9. Wash the sensors with neutral detergent using a soft cloth or sponge each time after use. Rinse completely with
water and store in a dry place.
10. Protect sensors by inserting the Sensor Protection Cap while not in use.
5. Calibration (Salinity)
Performing a Calibration:
1. While calibrating, make sure the sensor does not contact the 35ppt Salinity Standard
2. Solution bottom or sides within the measured sample.
3. Put the sensor part into 35ppt Salinity Standard Solution so that it is immersed fully.
4. Perform a measurement according to the measurement menu.
5. At this time, it is not necessary to calibrate it if the displayed figure is 35ppt.
6. When the displayed figure is not 35ppt, turn the calibration volume with a screwdriver until the displayed figure
becomes 35ppt. Confirm with 35ppt Salinity Standard Solution once again after calibration. If the displayed figure
does not indicate 35ppt, repeat this operation.
6. Replacement of the Battery
6.1 When to replace the batteries
When the
sign appears on the LCD display, your batteries are low and need replacement. Your tester will
automatically shut off when battery life is out. Your kit includes (3) replacement batteries (LR44).
6.2 How to replace the batteries
1. Open the cover in the back of the main body and pull out the used batteries.
2. Insert the (3) new battery (LR44) paying attention to the polarity (positive (+), negative (-)). Always replace all
(3) batteries at the same time for the best results.
3. Close the cover and turn on power to confirm whether the batteries were replaced correctly.
7.Troubleshooting
LCD display becomes dim
or stop working
Unstable measured value
8. Warranty
GmbH warrants for 24 months for material failures. Further claims are excluded.
The Warranty is prooved by the original purchase invoice.
If your
product does not appear to be working correctly or appears to be defective please contact your
dealer in the first instance.
Before calling your dealer please ensure you have read and understood the operating instructions. If you have any
questions your dealer cannot answer please contact us.
Status
Low battery life
/ battery failure
Contamination of sensors
Salinity or temperature is
not homogeneous
Cause
Replace batteries
Wash sensors with neutral detergent and rinse w/
water. Dry w/ cloth or tissue
Please refer to 4.2 (salinity measurement) and
1.3 (cautions on measuring)
Remedy
, 10/ 2005
5