READ AND SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS:
This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape
wire for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into
an outlet that is properly grounded.
人 小
DANGER - Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is
necessary, do not connect the grounding wire to either flat blade. The wire with insulation having an outer surface that is green with or without
yellow stripes is the grounding wire. If the grounding instructions are not completely understood, or if in doubt as to whether the product is
properly grounded, check with a qualified electrician or serviceman.
The $130 is for use on a nominal 115 V/60 Hz (S230 — 230 V/50 Hz), (S230A —
GROUNDED
230 V/60 Hz) circuit and has a grounding plug that looks like the plug illustrated in
OUTLET
ADAPTER
Sketch A, in Figure 1. A temporary adapter, which looks like the adapter
ζ
illustrated in Sketch B and C may be used to connect this plug to a 2-pole
receptacle as shown in Sketch B, if a properly grounded outlet is not available.
A
The temporary adapter should be used only until a qualified electrician can install
GROUNDING
a properly grounded outlet, Sketch A. The green colored rigid ear, tab, etc.
PIN
GROUNDED OUTLET
TAB FOR
extending from the adapter must be connected to a permanent ground. such as a
BOX
GROUNDING SCREW
properly grounded outlet box cover. Whenever the adapter is used, it must be
(A)
(B)
(©)
held in place by a screw.
Figure 1
ELECTRICAL:
The motor of this compressor has a thermal overload protector. If the motor should overheat, the overload protector will shut off the motor. If
this should occur shut the compressor off and allow the motor to cool (approximately 5 minutes). If the compressor fails to start, check for circuit
breakers activated or blown fuses, the compressor may need to cool further before attempting to restart. If the overload protector shuts off the
motor frequently, you may have a low voltage solution. Low voltage can also be suspected when:
1.
The motor does not get up to full power or speed.
2.
Fuses or circuit breakers activate when starting the compressor.
3.
Lights dim or remain dim when the compressor is started.
4.
Other motor operated appliances fail to operate properly. Too many motor operated appliances on the same circuit.
EXTENSION CORDS:
Make certain your extension cord is in good condition. Make certain your extension cord wire size is not less than 18 gauge for 25 feet, 16
gauge for 50 feet, and 14 gauge for 100 feet.