Step 8
Bracing
Bracing is required on stages with a height greater than 30." Users may choose either horizontal or diagonal bracing.
Follow the instructions below for the chosen bracing method.
A. Horizontal Bracing
1. Brace each corner and every third bay along each side, using two braces per bay. To install horizontal
braces:
A. Insert brace pins into stage legs.
B. Turn bracket until it is perpendicular with the stage. Bracket lip should rest flush against the outer
edge of the stage leg.
C. Tighten the hex nut on the front of the horizontal brace to secure the bracket.
D. Reverse the procedure to remove braces.
2. Use three braces per bay for heights greater than 48." The space between braces should be at least 12."
3. Internal braces should be placed in different rows than perimeter bracing to increase stability.
B. Diagonal Bracing
1. Brace each corner and every third bay along each side. Attach diagonal braces using 3/8" x 2-1/2" hex
bolts and wing nuts. Double brace stages when height exceeds 48."
2. When using double diagonal bracing, at least one of the braces should span the connection between the
1-1/2" and the 1-3/4" telescoping sleeve.
WARNING
Always consult the BilJax Application Department for proper bracing
requirements when stage height exceeds 5'6". (1.800.537.0540)