Installing the XL Dispenser cont.
3.
Prepare Dispenser Base Assembly for Installation
a)
Remove retaining screw on rear back of dispenser using supplied hex key.
b)
Turn dispenser base 30° then pull down to separate completely from main body, sliding over tubes and power cord. Refer to Diagram 4 and 5.
c)
Place main body aside.
d)
Activate dispenser swivel feature if desired by pushing out locking piece as shown in Diagram 6.
e)
Remove base casting from barbed mounting shaft by unscrewing locking nut.
f)
Position critical locking sleeve at base of barbed mounting shaft, ensuring it contacts the moulded stop. Refer to Diagram 7.
g)
Push barbed mounting shaft through underside of mount hole with barb facing down. Large D-washer is recommended to be used if there is room.
i.
Insert D-washer over barbed mounting shaft prior to insertion through bench if it is used. Refer to Diagram 7.
h)
Re-assemble base casting and locking nut with barbed mounting shaft. Take care to align flat face on barbed mounting shaft with flat face in hole of
base casting.
i)
Finger tighten locking nut.
j)
CHECK CRITICAL LOCKING SLEEVE IS STILL POSITIONED AT BASE OF BARBED MOUNTING SHAFT.
k)
Ensure barb is centred in mount hole and alignment of base is correct. Moderately tighten locking nut using multigrips or spanner. Avoid
overtightening the locking nut to avoid damaging the barbed mounting shaft. Refer to Diagram 8..
4.
Install Dispenser Main Body
a)
Feed all tubing and power cord through hole in dispenser base. Feed power cord first followed by tubes. Refer to Diagram 9.
b)
Gently pull all tubes and power cords, ensuring tubes aren't kinked or twisted. Do not attempt to force tubing or power cord through with a pointed
object as this may cause damage.
c)
Re-assemble dispenser base and main body by turning main body 30° in relation to dispenser base and pushing down. Gently pull tubing and power
cord downwards at the same time from underneath to prevent kinking and bunching.
d)
Turn dispenser main body straight once fully inserted and re-install retaining screw on rear back of dispenser.
e)
If swivel feature has been activated check dispenser now smoothly swivels 45° in each direction.
217mm
Dispenser Base
Template
Diagram 2
Bottom view
Tubing
removed
for clarity
Rotated
Dispenser
Diagram 4
Base
6
20mm
184.5mm
137.5mm
12.5mm
Bench
Thickness
1mm-48mm
Tubing
removed
for clarity
35mm
70mm
Diagram 3
Installing the XL Dispenser cont.
Large
D-Washer
Tubing
removed
for clarity
Diagram 5
Locking Nut
Base Casting
Ensure no
burrs are
present
Barbed
Mounting
Shaft
Diagram 6
Installing Underbench Module
1.
Flush Water Supply
Flush water supply before installation by connecting supplied 600mm flexible braided hose to the supply tap and running water into a bucket.
Blockages/unit malfunctions caused by debris are not covered by warranty.
2.
Install Underbench Module
Fit your Billi OmniOne in intended install location. Remove all protective films and packaging materials once installed.
3.
Connect Water Supply
Connect directly to cold water supply tap using the supplied 600mm flexible braided hose. Ensure there are no kinks or twists in the hose.
DO NOT TURN ON WATER SUPPLY.
4.
Connect Dispenser Tubing and Power Cord
Connect dispenser power cord and tubing as shown in Diagram 10 and 11. For Billi OmniOne Plus 9 refer to instructions on page 9 for Plus mixer
tap installation.
a)
Trim back dispenser tubes to avoid kinking and sagging from excessive length.
i. It is advised to leave 100mm of tubing in addition to minimum required length.
ii. Only trim PE tubes with a plastic tube cutter. Silicone tubes may be trimmed with a sharp knife or plastic tube cutter.
iii. Ensure all tubes are cut square and straight.
b)
Ensure all tubes are fully inserted and silicone tubes are secured with supplied spring clamps in drain connection kit.
c)
Ensure flat face of dispenser power cord is facing forwards when inserted.
IMPORTANT: Silicone boiling outlet tube (red) and silicone vent tube (grey) MUST NOT be kinked and must be installed with a continual fall and no sag.
Critical
locking
Sleeve
Diagram 7
Gasket
Tubes and
Power Cord
Large
D-Washer
Critical Locking
Diagram 8
Sleeve
Diagram 9
7