Billi Quadra 440 Kurulum Kılavuzu - Sayfa 5

Mutfak & Banyo Armatürleri Billi Quadra 440 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Billi Quadra 440 12 sayfaları. Tower dispenser
Ayrıca Billi Quadra 440 için: Kurulum Kılavuzu (8 sayfalar)

Billi Quadra 440 Kurulum Kılavuzu
Installation guide
Billi Quadra – Firewall Tower

Installing the Dispenser

IMPORTANT: This Billi appliance is to be installed by a licensed trades person in accordance
with AS/NZS 3500.1 and AS/NZ 3500.2 and in compliance with applicable state regulatory
requirements. For correct operation of this appliance, it is essential to observe the
manufacturer's instructions.
1. Benchtop Preparation
Two 10mm holes, and one 50mm
hole will need to be drilled into the
benchtop as shown in the template
shown in Diagram 5.
Note: UK will require a 64mm hole.
When drilling into timber/laminate it is
recommended to drill a small pilot
hole first. Then partially drill from
underneath before completely drilling
from above. This will help to prevent
chipping the benchtop.
For granite or marble benchtops we
recommend you use a certified stone
mason to pre-drill the holes.
Important:
Remove
all
burrs
around
the
holes
and
check
internal
bores
are
completely
smooth.
2. Cords and Tubing
Pull power cord through the 50mm
hole first. Then pull the remaining
silicone tubing and dispenser power
cord through the 50mm hole.
3. Securing
Diagram 5
Align the bolts with the two 10mm
holes and lower the dispenser into
position.
Ensure
the
gasket
is
correctly
aligned, then tighten the nuts on the
underside of the benchtop to secure
the dispenser.
Washer
Diagram 6
5