Aqua One Precision 9500 Manuel
Su Pompası Aqua One Precision 9500 için çevrimiçi göz atın veya pdf Manuel indirin. Aqua One Precision 9500 2 sayfaları. Air pump
Ayrıca Aqua One Precision 9500 için: Manuel (5 sayfalar)
Precision Air Pump 2500 / 7500 / 9500 / 12000
Important Safeguards
This appliance is not intended for use by children or infirm
persons without supervision. Young children should be
supervised to ensure that they do not play with the appliance.
Warning: To guard against injury, basic safety precautions
should be observed, including the following:
1. Read and follow all safety instructions before using this appliance.
2. Danger: To avoid possible electric shocks, special care should be
taken since water is employed in the use of aquarium equipment. For
each of the following situations do not attempt repairs yourself. Return
the appliance to an authorised service facility for service or discard the
appliance.
a) If the pump falls into water, do not reach for it, unplug it and then
retrieve it. If the electrical components of the appliance get wet, unplug
the appliance immediately (non immersible equipment only).
b) If the pump shows any sign of abnormal water leakage, immediately
unplug it from the power source.
c) Carefully examine the pump after installation. It should not be
plugged in when there is water on parts which are not intended to be
wet.
d) Do not operate any aquarium product if it has a damaged cord or
plug, or if it is malfunctioning, or dropped or damaged in any manner.
A "drip loop" (See the diagram) should be arranged by the user for each
cord connecting an aquarium component to a receptacle. The drip loop
is the part of the cord below the level of the receptacle or the connector
if an extension cord is used. It is used to prevent water traveling along
the cord and coming in contact with the receptacle. If the plug or
receptacle does get wet, do not unplug the appliance. Disconnect the
fuse or circuit breaker that supplies the power to the appliance, then
unplug and examine for presence of water in the receptacle.
3. Close supervision is necessary when the appliance is used by or near
children.
4. Always unplug the pump from the electrical outlet, when not in use,
before putting on or taking off parts, before any type of maintenance,or
cleaning. Never yank the cord to pull it from the outlet. Grasp the plug
and unplug to disconnect.
5. Do not use the pump for reasons other than the intended use. The
use of attachments that are not recommended or sold by the pump
manufacturer may cause the product to be unsafe. This is not
recommended.
6. Do not install or store the pump where it will be exposed to weather or
temperatures below freezing.
7. Make sure any component mounted on a tank is securely installed
before operating it.
8. Read and observe all the important notices on the pump.
9. Ensure input voltage is the same voltage as your local power supply.
10. If an extension cord is necessary, a cord with a proper rating should
be used. Care should be taken to arrange the cord so that it will not be
tripped or pulled.
11. A G.F.C.I (Ground fault circuit interrupter) & surge protector is
recommended for all electrical appliances.
12. Ensure your hand is dry when turning the power switch on/off and
when inserting/removing the power cord from the receptacle.
13. If you are in any doubt about the electrical installation or safety of this
product you must consult a qualified electrician.
Drip loop
Before First Use / Preparation
Read and follow all the instructions, even if you feel you are familiar with
the product and find a place to keep the instructions handy for future
reference. Your attention is drawn particularly to the sections concerning
"IMPORTANT SAFEGUARDS" and the "GUARANTEE CONDITIONS".
Please insure you retain your original purchase receipt in the event that
guarantee service is required.
Carefully unpack the pump making sure you keep all the packing
material until all the parts of the product have been found and the
product has been assembled.
This Product is shipped to you in a factory sealed carton. Should the
Product be damaged, dropped, malfunctions in any way contact the
retailer where the product was purchased for inspection.
Hints & Tips for Best Results
Air Stone:
• Replace the Air Stone every 6 months or when it shows signs of
deterioration.
• If being used in salt water a plastic or ceramic air stone is
recommended.
Trouble Shooting
PUMP DOES NOT WORK
1. Ensure the plug is inserted correctly and the switch is in the on
position
THE MOTOR IS WORKING, BUT THERE IS NO AIR COMING
OUT OF THE PUMP.
1. Check that the Air Line is not kinked
2. Check the Air Stone and replace if needed.
3. There is a rubber diaphragm inside the pump which may have warn
out and may require replacing. Consult your Aqua One retailer.
4. The Flapper valves in the pump may have become dirty or brittle and
require replacing. Consult your Aqua One retailer.
5. Turn the pump up. Models 2500 to 9500 have a switch located on
either the top or side of the pump. Model 12000 has a control knob
located on top of the pump.
THE PUMP IS VERY NOISE
1. Check that the Air Line is not kinked
2. Check the Air Stone and replace if needed.
3. There is a rubber diaphragm inside the pump which may have warn
out and may require replacing.
4. There may be to much back pressure on the pump. (It is to small for
your application)
For Guarantee Conditions,
please refer to the Guarantee
conditions listed at the back
of this instruction sheet.