Problem
Excessive intervention of the
thermal protection
Lack of water leakage in the
first minute after starting
The pump starts without
water
Insufficient flow of water
Failure to prime
Little reach
The engine does not start
and makes noise
Water leaks in
function
NOTE
CPA srl excludes any liability for non-compliance with the safety standards in force for the individual technical sectors affected by this
document.
The information contained in this manual may vary at the discretion of the editor, without notice, together with the changes to the product in
question in this document: it will be the responsibility of the customer to verify the persistent correspondence of the product to the information
sheet when placing the order.
www.cpa-piscine.it
Cause
Air intake from the seal
mechanical
Not correct voltage
The impeller is hindered in rotation
Defective capacitor
Air infiltration in the suction pipe
Water leakage from the pipeline o
from the pump
Loss of water from the estate
mechanics
Reached the level limit
suction
Filter, pre-filter and / or valves
clogged or blocked
Impeller blocked
Presence of air
Transparent perforated plastic cover
Wrong motor direction
High absorption
Wrong voltage
No water in the filter basket or in the
pump body
Absence of water for priming
Presence of air
Wrong motor direction
High absorption
Wrong voltage
Blockage in the filter basket
Dirt in the pump housing
Impeller block
Damage to the mechanical seal or
dirt absorbed by it
Solution
Replace the mechanical seal
Check the voltage present on the line
(qualified technical personnel)
Check the integrity of the
impeller. Clean the impeller
Replace the capacitor
Check and if necessary repair the pipe,
checking its hermetic seal
Repair the piping, pump or connecting
points between parts
Replace the mechanical seal
Check the water level in the suction basin
Verify clean / repair the components
associated with the piping and the pump
Disassemble the pump and carefully
clean the pump body and impeller
(qualified personnel only)
Check the mechanical joint
Clean the clear plastic cover and check
the gasket
Electrical check
Adjust the absorption
Check the voltage of the power line
Fill the filter basket or pump
housing with water
Fill the suction tube with water
Check that the lid is closed
correctly
Check the electrical wiring
Adjust the absorption
Voltage check
Clean the filter basket
Clean the pump body
Impeller washing
Clean the mechanical seal or change it