Aqua PRO DV FLO Kullanıcı El Kitabı - Sayfa 3
Su Pompası Aqua PRO DV FLO için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Aqua PRO DV FLO 20 sayfaları.
General Safety (continued)
ALWAYS FOLLOW BASIC SAFETY PRECAUTIONS WITH THIS EQUIPMENT, INCLUDING:
□ Provide sufficient ventilation to maintain air temperature below the maximum ambient temperature rating shown on the motor
nameplate. Pump house must allow adequate ventilation to assure the ambient temperature remains below the motor rating when
the pump is operating.
□ Locate the pump on a non combustible surface. The surface should be hard, level, dry, well ventilated, and out of direct sunlight.
The surrounding area should provide protection from the elements and allow sufficient space for maintenance and service. Ensure
the drainage will flow away from the pump. To reduce vibration and pipe stress, use anchor bolts to secure pump base to surface.
Support the suction and discharge piping.
□ Design the piping system to allow the pump suction inlet height to be as close to water level as possible. Mount the pump below
water level for easy priming. If the pump must be located above the filled water level, keep the vertical distance to a minimum. Use
short, direct piping to the suction as this will minimize friction loss.
WARNING: Fire and burn hazard. Motors run at high temperatures. Do not allow leaves, debris, or foreign matter to collect around the
pump motor. Keep ventilation holes open. Allow the motor to cool before handling. Keep flammable liquids away.
□ If the thermal overload protection in the motor trips or if the GFCI trips, determine the reason and correct the problem before re-
starting pump.
□ Use rigid or flexible PVC pipe. Ensure pipe ends are clean and free of any flash caused by cutting. Use the proper glue for the type of
pipe selected.
NOTE: Use a supplier recommended primer to ensure glued joints are secure. Many local codes require primer with a purple tracer to verify
primer use.
Consider climatic conditions when applying adhesives. Atmospheric conditions with high humidity will make the adhesive action of certain
glues less effective. Follow the manufacturer's instructions.
POOL SAFETY GUIDELINES
RESPONSIBLE ADULT SUPERVISION
Constant and responsible adult supervision is mandatory in the pool or spa environment. Always supervise children around pools and spas.
Never allow a child to play in a way that could permit the child's hair to come near the drain cover.
DRAINS, SUCTION FITTINGS, AND JETS
Keep hair and clothing away from the suction fitting drain cover. Wear a bathing cap or pin hair up if you have long hair. Current grates and
covers help prevent body or hair entrapment. Make sure that drain covers meet the ANSI/ASME A112.19.8 standard. Safety doors should be
installed in all pool cleaner wall suction lines. Pools or spas with drain covers that are broken, missing, or not adequately secured should
not be used until the proper replacement has been installed.
ELECTRICAL HAZARDS
A licensed electrician, experienced in swimming pools and spas, should inspect your equipment to make sure everything is properly
grounded, bonded, and protected by proper GFCI circuits according to Article 680 of the National Electric Code.
DROWNING PREVENTION
Install and routinely inspect fences, self-closing and latching gates, baby barrier fences, and alarms. Eliminate incidental routes to pool
including machinery or equipment that provides a route over fencing into pool area. INDOOR INSTALLATIONS
Pools and spas located indoors must comply with ANSI/ASHRAE (American Society of Heating, Refrigeration and Air-Conditioning Engineers)
standard 62-2001 to ensure adequate ventilation and safe use.
WARNING SIGNS
Protect your family and guests. Make sure that all warning signs provided by the manufacturer, builder, or installer are displayed according
to the manufacturer's specifications.
3
Please contact 1-877-278-2797 for further assistance.
ECOAQUAPRO.COM