Aqua PRO ECO550 Kurulum ve Kullanım Kılavuzu - Sayfa 9
Isı Pompası Aqua PRO ECO550 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Aqua PRO ECO550 20 sayfaları. Swimming pool heat pump
Ayrıca Aqua PRO ECO550 için: Kurulum ve Kullanım Kılavuzu (20 sayfalar)
Options for protecting devices and cable specification
※
Breaker
Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10 m. If power cord is
>10 m, wire diameter must be increased. The signal cable can
be extended to 50 m at most.
1.
Installation and Requirements
The swimming pool heater must be installed by a pool professional. End
users are not qualified to install the heater. Damage may occur to the
heater or threaten the safety of the user.
A. Installation
1) The swimming pool heater should be installed in a location with good
ventilation;
2) The frame must be fixed by bolts (M10) to concrete foundation or
brackets. The concrete foundation must be solid and fastened; the
bracket must be strong and antirust treated;
3) Don't stack substances that will block air flow near inlet or outlet area,
and no barrier within 20in behind the main heater, or the efficiency of the
heater will be reduced or even haulted;
4) The heater needs an appended pump (Supplied by the user). The
recommended pump specification-flux: refer to Technical Parameter,
Max. lift ≥10m;
5) When the heater is running, there will be condensation water
MODEL
Rated Current A
Rated Residual
Action Current mA
Fuse
Power Cord
Signal cable
A
(AWG)
(AWG)
8
ECO550
20
30
20
3x12
3x20