CPE C218 Manuel - Sayfa 19
Su Pompası CPE C218 için çevrimiçi göz atın veya pdf Manuel indirin. CPE C218 19 sayfaları. Portable pump
CPE Systems Inc.
|
Table 6: Diagnostics and Fault Elimination
The "RDY" and "ERR" LED status displays on the front of the inverter provide some quick
information about certain operating states.
"RDY" LED (blue)
Off
On
Blinking (1 Hz)
Blinking (2 Hz)
On
Both LEDS are blinking in a rapidly alternating mode
Both LEDs are blinking in a very rapidly synchronous mode
www.cpesystems.com
"ERR" LED (red)
Off
On
Off
Blinking fast (4 Hz)
Off
Blinking fast (4 Hz)
On
Lit ever 1.5s for a short time
On for a short time every 1s
Off
Blinking fast (4 Hz)
Blinking (1 Hz)
|
+1 800 668 2268
Status/meaning
No supply voltage.
Initialization (inverter is started).
Safe torque off (STO) active.
Safe torque off (STO) active, warning
active.
Inverter inhibited.
Inverter disabled, warning active.
Inverter disabled, error active.
Inverter inhibited, no DC-bus voltage.
USB module is connected, 5-V
supply voltage for the USB module is
available.
Inverter enabled.
The motor rotates according to the
specified setpoint or quick stop active.
Inverter enabled, warning active.
The motor rotates according to the
specified setpoint or quick stop active.
Inverter enabled, quick stop as
response to fault active.
Firmware update active.
"Visual tracking" function is active.
|
19