LIGHTING INSTRUCTIONS 
 
Lighting pilot 
The pilot light on the appliance has been set at the factory. A screwdriver may be required for the 
first lighting to adjust the flame for your elevation.   
 
1.  Turn off the manual valve and wait 5 minutes to clear the gas. 
2.  Turn all knobs to the "OFF" position. 
3.  Hold an ignition source (match) at the pilot. When the flame is established, remove the ignition 
source. 
4.  Turn  the  burner  knobs  to  "ON".  If  the  burner  does  not  ignite,  promptly  open  the  pilot  valve 
more. If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The 
pilot  flame  should  be  as  small  as  possible  but  large  enough  to  guarantee  reliable  ignition  of  the 
burners when the knobs are turned to "ON". 
 
Lighting main burner 
To light burner, turn knob to "ON." Then back off to the desired flame level. The range of adjustment 
is virtually infinite between "ON" and "OFF".   
 
Main burner air supply: 
 
1.  For efficient burner operation, a proper balance of gas volume and primary air supply must be 
maintained  which  will  result  in  complete  combustion.  Insufficient  air  supply  results  in  a  yellow 
streaming flame. Primary air supply is controlled by an air shutter on the front of the burner. 
2.  Loosen the screws on the front of the burner and adjust the air shutter to eliminate the yellow 
tips of the burner flame. Lock the air shutter in place by tightening the screws. 
 
CAUTION 
All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is all 
that is required to put the unit in service. 
 
Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the 
units' sides or back. Avoid wall type fans which create air cross‐currents within a room. 
 
It is also necessary that sufficient air should be allowed to enter the room to compensate for the 
amount of air removed by any ventilating system. Otherwise, a subnormal atmospheric pressure will 
occur, affecting operation and causing undesirable working conditions. 
 
A properly designed and installed hood will act as the heart of the ventilating system for the room 
or  area  in  which  the  unit  is  installed,  and  will  leave  the  unit  independent  of  changing  draft 
conditions. 
 
All valves must be checked and lubricated periodically. This must be done by an authorized service 
representative in your area.