CPS IAQPRO SmartAir Kullanıcı El Kitabı - Sayfa 6
Ölçüm Cihazları CPS IAQPRO SmartAir için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. CPS IAQPRO SmartAir 18 sayfaları. Professional indoor air quality meter
Ayrıca CPS IAQPRO SmartAir için: Kullanıcı El Kitabı (9 sayfalar), Hızlı Başlangıç ve Sorun Giderme Kılavuzu (8 sayfalar)
SPECIFICATIONS (CONT'D)
Air Quality Factor Measurement
Temperature
Pressure
Building Pressure
DP
rH
Relative Humidity
Indoor Comfort Zone
Temperature &
(Heating/Cooling
Season)
Total Volatile Organic
tVOC's
CO 2
Carbon Dioxide
Fine Particulate
PM 2.5
PM 10
Particulate Matter
* After being powered ON. If stored in temperature extremes, let SmartAir adjust (unplugged) to indoor temperature for 6~8 hours.
** Accuracy spec applies up to 600 ppb. See Quick Start Guide or Owner's Manual for additional use instructions.
6
SmartAir Sensor Specifications
Accuracy
Temperature
±2.3 ºF (±1.3 ºC)
±0.100 in.WC
(±0.25 hPa)
Dew Point
±2.3º F (± 1.3 ºC)
Temperature
± 5% Of Reading
±5% of Reading
+/- 2.3F (+/- 1.3C),
Humidity
+/-5% of Reading
±(50 ppb + 15%)
Compounds
± (100 ppm +3% Of
Reading)
± 25ug/m3 for < 100
Matter
±25% for > 100ug/m3
Minimum Time
To Acquire
Accurate Data*
Immediate
5 Minutes To 60
Minutes
3 Minutes
ug/m3;
Immediate
Values Displayed
In App
Minimum Maximum
32F (0C)
122F (50C)
120 in. WC
441 in. WC
(300 hPa)
(1100 hPa)
32F (0C)
122F (50C)
10%
95%
61F (16C) &
93F (34C) &
10% r.H.
95% r.H.
0 ppb
5,000 ppb**
0 ppm
5,000 ppm
0 ug
400 ug
0 ug