4. Next, with the mirror facing up, place the mirror cell assembly under
running, room temperature water for about (1) minute.
5. Turn the water off and pour a generous amount of the premixed
distilled water solution over the surface of the primary mirror.
6. Then take the cotton balls and saturate them with the premixed distilled
water solution and lightly swirl them on the surface of the mirror. You
don't have to swirl the mixture so as to create a lot of bubbles on the
surface, agitate it only enough to see a hint of the soap in the solution.
That will usually be sufficient to remove most stubborn dirt or stains on
the surface.
7. Next, with the mirror facing up, place the mirror cell assembly under
running, room temperature water for (1) minute, except after one
minute turn off the water and quickly flush the surface with a generous
amount of distilled water.
8. After the surface has been flushed with distilled water quickly turn the
mirror cell assembly on its side to drain off excess water. Then take the
bathroom tissue pad and lightly and gently blot the remaining water
from the surface.
9. Next, using a paper towel, carefully wipe up the water on the large and
small platters of the primary mirror cell. Avoid turning the assembly
upside down, and also, avoid touching the freshly cleaned mirror
surface. Inspect and repeat procedure if necessary. Reinstall mirror cell
assembly in tube assembly.
Because of the crucial nature of the secondary mirror alignment, it is advisable to
remove and/or clean it only if there is an excessive amount of contaminants on
the surface. To remove the secondary, loosen the hex nut/threaded rod
assembly that secures the mirror itself to the "L" shaped stalk. If you need
remove the secondary for cleaning be sure to measure the exact distance that
the second hex nut is threaded into the brass rod. That will mark the position
when the secondary is reinstalled. If possible, use cleaning methods that allow
the secondary mirror to remain in place. Try blowing the surface off with low
pressure air or wiping the surface with a soft camel hair brush and then gently
rake the surface with a bathroom tissue pad dampened with a small quantity of
alcohol or methanol. And as always, DGM Optics™ will be glad to give technical
support if needed.