Dell DX6004S Kullanıcı Kılavuzu - Sayfa 34

Sunucu Dell DX6004S için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Dell DX6004S 46 sayfaları. Document
Ayrıca Dell DX6004S için: Tamamlayıcı Kılavuz (4 sayfalar), Kurulum ve Yapılandırma Kılavuzu (43 sayfalar), Kurulum ve Yapılandırma Kılavuzu (35 sayfalar), Başlangıç Kılavuzu (28 sayfalar), Uyarı (28 sayfalar), Uyarı (20 sayfalar), Genel Bakış (19 sayfalar), Yapılandırma Kılavuzu (9 sayfalar), Yapılandırma Kılavuzu (9 sayfalar), Yayın Notu (8 sayfalar), Yapılandırma Kılavuzu (7 sayfalar), Yayın Notu (6 sayfalar), Yayın Notu (5 sayfalar), Sürüm Notları (5 sayfalar), Başlangıç Kılavuzu (49 sayfalar)

Dell DX6004S Kullanıcı Kılavuzu
Dell Management Console—Centrally monitors the status of Dell
systems. For more information about installing and using DMC, see the
Dell Management Console User's Guide at support.dell.com/manuals.

Reinstalling the Operating System

The operating system is preinstalled on the DX Cluster Services Node. After a
multiple disk failure of the DX6a00 system RAID group, reinstall the
operating system:
1 Replace the failed disks.
2 Create a RAID 5 disk group across all disks of the DX Cluster Services

Node.

3 Reinstall the operating system. For more information on replacing the
drive, see "Recovering From Disk Failures" on page 33.
NOTE:
If the RAID group has not failed and you are reinstalling the operating
system, skip "Configuring and Managing RAID" on page 34.

Configuring and Managing RAID

The BIOS Configuration Utility (<Ctrl><R>), is a storage management
application embedded on the PERC H700 card that configures and maintains
RAID disk groups and virtual disks. The BIOS Configuration Utility is
independent of the operating system and is available during system startup.
See the Dell PowerEdge RAID Controller (PERC) H700 and H800 User's
Guide at support.dell.com/manuals for specific instructions on the BIOS
Configuration Utility and virtual disk management.
Create a single RAID 5 group across all six internal drives. When creating the
RAID group, configure two virtual disks.
Set virtual disk 0 to 75 GB
Set virtual disk 1 to size of the remaining capacity
34
Disaster Recovery