Dell E103S Kurulum ve Servis Kılavuzu - Sayfa 29
Sunucu Dell E103S için çevrimiçi göz atın veya pdf Kurulum ve Servis Kılavuzu indirin. Dell E103S 34 sayfaları.
Figure 21. Installing a reverse air flow (RAF) power supply unit
Next steps
1. Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION:
When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE:
When installing, hot swapping, or hot adding a new PSU, wait for 15 s for the system to recognize the PSU and
determine its status. The PSU redundancy may not occur until discovery is complete. The PSU status indicator turns
green to indicate that the PSU is functioning properly.
NOTE:
For certain premium configurations with high power consumption, system PSU might stay with 2+0 mode only, 1+1
redundant mode is not available.
NOTE:
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the
Lifecycle Controller User's Guide at
Installing a power supply unit blank
Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in
3.
Remove the
PSU.
NOTE:
Install the power supply unit (PSU) blank only in the second PSU bay.
Steps
Align the PSU blank with the PSU bay and push it into the PSU bay until it clicks into place.
https://www.dell.com/idracmanuals
Safety
instructions.
Before working inside your
system.
Installing and removing system components
29