Dell Equallogic PS6010x Donanım Kılavuzu - Sayfa 16
Sunucu Dell Equallogic PS6010x için çevrimiçi göz atın veya pdf Donanım Kılavuzu indirin. Dell Equallogic PS6010x 50 sayfaları. Equallogic
Ayrıca Dell Equallogic PS6010x için: Genel Bakış (7 sayfalar), Hızlı Referans Kılavuzu (2 sayfalar)
Figure 6. Sixteen-Node iSCSI SAN-Attached Cluster
1. public network
2. private network
3. cluster nodes (2-16)
4. Gigabit or 10 Gigabit Ethernet switches
5. storage system
Cabling One iSCSI SAN-Attached Cluster To The Dell EqualLogic PS Series Storage Array(s)
1.
Connect cluster node 1 to the iSCSI switches:
a) Connect a network cable from iSCSI NIC 0 (or NIC port 0) to the network switch 0.
b) Connect a network cable from iSCSI NIC 1 (or NIC port 1) to the network switch 1.
2.
Repeat step 1 for each cluster node.
3.
Connect the Dell EqualLogic PS Series storage array(s) to the iSCSI switches.
For more information on cabling the specific storage arrays, see the following sections.
Cabling The Dell EqualLogic PS4110/PS6110 Storage Arrays
1.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 0.
2.
Connect a network cable from the network switch 1 to Ethernet 0 on the control module 1.
3.
Repeat steps 1 and 2 to connect the additional Dell EqualLogic PS4110/PS6110 storage array(s) to the iSCSI
switches.
16