Dell Force10 S25 Series Yapılandırma Kılavuzu - Sayfa 6

Sunucu Dell Force10 S25 Series için çevrimiçi göz atın veya pdf Yapılandırma Kılavuzu indirin. Dell Force10 S25 Series 8 sayfaları. Basic layer 2 setup and buffer tuning of the s25p for storage environments
Ayrıca Dell Force10 S25 Series için: Hızlı Başlangıç Kılavuzu (27 sayfalar)

Dell Force10 S25 Series Yapılandırma Kılavuzu
Figure 2 Defining a Buffer Profile for ASIC Queues [in bytes]
!
buffer-profile fp eql-hig
buffer dedicated queue0 3 queue1 3 queue2 3 queue3 3 queue4 3 queue5 3 queue6 3 queue7 3
buffer dynamic 1257
Force10#
Figure 3 Configuring Internal ASIC Buffers in Stack Unit 0
!
buffer fp-uplink stack-unit 0 port-set 0 buffer-policy eql-hig
buffer fp-uplink stack-unit 0 port-set 1 buffer-policy eql-hig
Force10#
Figure 4 Applying the Buffer Profile to all 1Gig and 10Gig Ports
!
interface range gi 0/1 - 24 , te 0/25 - 28
buffer-policy eql-fp
Force10#
Figure 5 Flow Control for 1Gig Interfaces
!
interface range gi 0/1 - 24
flow-control rx on tx on
Force10#
Figure 6 Refresh Interval for Interface Statistics
!
rate-interval 30
Force10#
Figure 7 Configuring Ten Gig Ports [assuming all four 10Gig interfaces are available]
!
interface range te 0/25 - 28
no ip address
mtu 9252
switchport
flowcontrol rx on tx on threshold 1024 1024 1054
rate-interval 30
no shutdown
Force10#
Figure 8 Assigning Ports to a VLAN
!
interface vlan 2
untagged gi 0/1 - 24, te 0/25 - 28
Force10#
6
Basic Layer 2 Setup and Buffer Tuning of the S25P for Storage Environments